The effect of MR scanner noise on auditory cortex activity using fMRI

被引:48
作者
Scarff, CJ
Dort, JC
Eggermont, JJ
Goodyear, BG
机构
[1] Univ Calgary, Dept Psychol, Behav Neurosci Res Grp, Calgary, AB T2N 1N4, Canada
[2] Univ Calgary, Fac Med, Dept Surg, Auditory Res Program, Calgary, AB T2N 1N4, Canada
[3] Univ Calgary, Dept Physiol & Biophys, Calgary, AB T2N 1N4, Canada
[4] Univ Calgary, Dept Radiol, Seaman Family MR Res Ctr, Calgary, AB T2N 1N4, Canada
[5] Univ Calgary, Dept Clin Neurosci, Seaman Family MR Res Ctr, Calgary, AB T2N 1N4, Canada
关键词
brain; audiology; tonotopicity; functional imaging; physiology;
D O I
10.1002/hbm.20043
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Auditory functional magnetic resonance imaging (fMRI) studies are limited by the presence of noise produced by echo planar imaging (EPI). The current study quantifies the effect of MR scanner noise on psychophysical measures of the perception of loudness and on measures of tonotopy, the representation of auditory frequencies within the auditory cortex. Seven normal hearing adults were examined using tones of 5 different auditory frequencies (250, 500, 1,000, 2,000, 4,000 Hz) of equal loudness. Using an imaging protocol with peak MR scanner noise at 1,460 Hz, the perception of loudness and detectable fMRI activity in response to a 1-kHz tone was less compared to other frequencies. When the imaging protocol was changed such that peak MR scanner noise occurred at 2,080 Hz, the perception of loudness and detectable fMRI activity in response to a 2-kHz tone was less compared to other frequencies. The reduction in the measured fMRI activity for tones near scanner frequencies may be due to an inflated scanner-induced baseline at those frequencies. In addition, fMRI activity decreased with increasing frequency, possibly due to the upward spread of masking of low-frequency, high-intensity tonal stimuli or the proximity of low-frequency core and belt areas of the auditory cortex. These results demonstrate the direct effect of scanner noise and high-intensity tonal stimuli on measurements of auditory cortex tonotopy. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:341 / 349
页数:9
相关论文
共 49 条
[1]  
[Anonymous], 1995, Hearing (Handbook of Perception and Cognition)
[2]   Functional MRI of brain activation induced by scanner acoustic noise [J].
Bandettini, PA ;
Jesmanowicz, A ;
Van Kylen, J ;
Birn, RM ;
Hyde, JS .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (03) :410-416
[3]  
Bandettini PA, 1997, NEUROSURG CLIN N AM, V8, P345
[4]   Event-related fMRI of the auditory cortex [J].
Belin, P ;
Zatorre, RJ ;
Hoge, R ;
Evans, AC ;
Pike, B .
NEUROIMAGE, 1999, 10 (04) :417-429
[5]  
BERTRAND O, 1991, ACTA OTO-LARYNGOL, P116
[6]   The MR tomograph as a sound generator:: fMRI tool for the investigation of the auditory cortex [J].
Bilecen, D ;
Radü, EW ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :934-937
[7]   Tonotopic organization of the human auditory cortex as detected by BOLD-FMRI [J].
Bilecen, D ;
Scheffler, K ;
Schmid, N ;
Tschopp, K ;
Seelig, J .
HEARING RESEARCH, 1998, 126 (1-2) :19-27
[8]   Detection versus estimation in event-related fMRI: Choosing the optimal stimulus timing [J].
Birn, RM ;
Cox, RW ;
Bandettini, PA .
NEUROIMAGE, 2002, 15 (01) :252-264
[9]   Analysis of acoustic noise in MRI [J].
Cho, ZH ;
Park, SH ;
Kim, JH ;
Chung, SC ;
Chung, ST ;
Chung, JY ;
Moon, CW ;
Yi, JH ;
Sin, CH ;
Wong, EK .
MAGNETIC RESONANCE IMAGING, 1997, 15 (07) :815-822
[10]   MRI acoustic noise: Sound pressure and frequency analysis [J].
Counter, SA ;
Olofsson, A ;
Grahn, HF ;
Borg, E .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) :606-611