CT screening for lung cancer: Suspiciousness of nodules according to size on baseline scans

被引:272
作者
Henschke, CI
Yankelevitz, DF
Naidich, DP
McCauley, DI
McGuinness, G
Libby, DM
Smith, JP
Pasmantier, MW
Miettinen, OS
机构
[1] Cornell Univ, Weill Med Coll, Dept Radiol, New York, NY 10021 USA
[2] Cornell Univ, Weill Med Coll, Dept Med, New York, NY 10021 USA
[3] NYU, Ctr Med, Dept Radiol, New York, NY USA
[4] McGill Univ, Dept Epidemiol & Biostat, Montreal, PQ, Canada
关键词
cancer screening; lung; CT; nodule; lung neoplasms;
D O I
10.1148/radiol.2311030634
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the frequency with which a particular, possibly optimal work-up of noncalcified nodules less than 5.0 mm in diameter identified on initial computed tomographic (CT) images at baseline screening leads to a diagnosis of malignancy prior to first annual repeat screening, compared with a possibly optimal work-up of larger nodules. MATERIALS AND METHODS: Two series of baseline CT screenings in high-risk people were retrospectively reviewed. The first series (n = 1,000) was performed in 1993-1998; the second (n = 1,897), in 1999-2002. In each series, cases in which the largest noncalcified nodule detected was less than 5.0 mm in diameter and those in which it was 5.0-9 mm were reviewed to determine whether diagnostic work-up prior to first annual repeat screening showed or would have shown nodule growth and led or would have led to a diagnosis based on biopsy or surgical specimens. RESULTS: The frequency with which malignancy was or could have been diagnosed when the largest noncalcified nodule was less than 5.0 mm in diameter was 0 of 378, whereas when the largest noncalcified nodule was 5.0-9 mm in diameter, the frequency was 13 or 14 of 238. If persons with only nodules smaller than 5.0 mm had merely been referred for first annual repeat screening without immediate further work-up, the referrals for such work-up would have been reduced by 54% (from 817 [28%] to 385 [13%] of 2,897). CONCLUSION: In modern CT screening for lung cancer at baseline, detected noncalcified nodules smaller than 5.0 mm in diameter do not justify immediate work-up but only annual repeat screening to determine whether interim growth has occurred. (C) RSNA, 2004.
引用
收藏
页码:164 / 168
页数:5
相关论文
共 8 条
  • [1] American College of Radiology Imaging Network, 6654 ACRIN
  • [2] Screening for early lung cancer with low-dose spiral CT: Prevalence in 817 asymptomatic smokers
    Diederich, S
    Wormanns, D
    Semik, M
    Thomas, M
    Lenzen, H
    Roos, N
    Heindel, W
    [J]. RADIOLOGY, 2002, 222 (03) : 773 - 781
  • [3] Screening for lung cancer: the early lung cancer action approach
    Henschke, CI
    Yankelevitz, DF
    Smith, JP
    Miettinen, OS
    [J]. LUNG CANCER, 2002, 35 (02) : 143 - 148
  • [4] Early Lung Cancer Action Project: overall design and findings from baseline screening
    Henschke, CI
    McCauley, DI
    Yankelevitz, DF
    Naidich, DP
    McGuinness, G
    Miettinen, OS
    Libby, DM
    Pasmantier, MW
    Koizumi, J
    Altorki, NK
    Smith, JP
    [J]. LANCET, 1999, 354 (9173) : 99 - 105
  • [5] STATISTICAL CONTROL OF COUNTING EXPERIMENTS
    LANCASTER, HO
    [J]. BIOMETRIKA, 1952, 39 (3-4) : 419 - 422
  • [6] SOME REASONS FOR NOT USING YEATS CONTINUITY CORRECTION ON 2X2 CONTINGENCY-TABLES - COMMENT
    MIETTINEN, OS
    [J]. JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1974, 69 (346) : 380 - 382
  • [7] Lung cancer screening with CT: Mayo Clinic experience
    Swensen, SJ
    Jett, JR
    Hartman, TE
    Midthun, DE
    Sloan, JA
    Sykes, AM
    Aughenbaugh, CL
    Clemens, MA
    [J]. RADIOLOGY, 2003, 226 (03) : 756 - 761
  • [8] CT screening for lung cancer
    Swensen, SJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) : 833 - 836