An improved model for prediction of retention times of tryptic peptides in ion pair reversed-phase HPLC - Its application to protein peptide mapping by off-line HPLC-MALDI MS

被引:233
作者
Krokhin, OV
Craig, R
Spicer, V
Ens, W
Standing, KG
Beavis, RC
Wilkins, JA
机构
[1] Univ Manitoba, Dept Phys & Astron, Winnipeg, MB R3T 2N2, Canada
[2] Univ Manitoba, Manitoba Ctr Proteom, Winnipeg, MB R3E 3P4, Canada
关键词
D O I
10.1074/mcp.M400031-MCP200
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The proposed model is based on the measurement of the retention times of 346 tryptic peptides in the 560- to 4,000-Da mass range, derived from a mixture of 17 protein digests. These peptides were measured in HPLC-MALDI MS runs, with peptide identities confirmed by MS/MS. The model relies on summation of the retention coefficients of the individual amino acids, as in previous approaches, but additional terms are introduced that depend on the retention coefficients for amino acids at the N-terminal of the peptide. In the 17-protein mixture, optimization of two sets of coefficients, along with additional compensation for peptide length and hydrophobicity, yielded a linear dependence of retention time on hydrophobicity, with an R-2 value about 0.94. The predictive capability of the model was used to distinguish peptides with close m/z values and for detailed peptide mapping of selected proteins. Its applicability was tested on columns of different sizes, from nano- to narrow-bore, and for direct sample injection, or injection via a pre-column. It can be used for accurate prediction of retention times for tryptic peptides on reversed-phase (300-Angstrom pore size) columns of different sizes with a linear water-ACN gradient and with TFA as the ion-pairing modifier.
引用
收藏
页码:908 / 919
页数:12
相关论文
共 53 条
  • [1] A mass spectrometric journey into protein and proteome research
    Aebersold, R
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (07) : 685 - 695
  • [2] Mass spectrometry in proteomics
    Aebersold, R
    Goodlett, DR
    [J]. CHEMICAL REVIEWS, 2001, 101 (02) : 269 - 295
  • [3] Enrichment of integral membrane proteins for proteomic analysis using liquid chromatography-tandem mass spectrometry
    Blonder, J
    Goshe, MB
    Moore, RJ
    Pasa-Tolic, L
    Masselon, CD
    Lipton, MS
    Smith, RD
    [J]. JOURNAL OF PROTEOME RESEARCH, 2002, 1 (04) : 351 - 360
  • [4] THE ISOLATION OF PEPTIDES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING PREDICTED ELUTION POSITIONS
    BROWNE, CA
    BENNETT, HPJ
    SOLOMON, S
    [J]. ANALYTICAL BIOCHEMISTRY, 1982, 124 (01) : 201 - 208
  • [5] ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES
    FENN, JB
    MANN, M
    MENG, CK
    WONG, SF
    WHITEHOUSE, CM
    [J]. SCIENCE, 1989, 246 (4926) : 64 - 71
  • [6] FITCHETT JR, 2001, 49 ASMS C MASS SPECT
  • [7] Cyclization of N-terminal S-carbamoylmethylcysteine causing loss of 17 Da from peptides and extra peaks in peptide maps
    Geoghegan, KF
    Hoth, LR
    Tan, DH
    Borzillerl, KA
    Withka, JM
    Boyd, JG
    [J]. JOURNAL OF PROTEOME RESEARCH, 2002, 1 (02) : 181 - 187
  • [8] Quantitative proteomic analysis using a MALDI quadrupole time-of-flight mass spectrometer
    Griffin, TJ
    Gygi, SP
    Rist, B
    Aebersold, R
    Loboda, A
    Jilkine, A
    Ens, W
    Standing, KG
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (05) : 978 - 986
  • [9] PREDICTION OF PEPTIDE RETENTION TIMES IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. DETERMINATION OF RETENTION COEFFICIENTS OF AMINO-ACID-RESIDUES OF MODEL SYNTHETIC PEPTIDES
    GUO, DC
    MANT, CT
    TANEJA, AK
    PARKER, JMR
    HODGES, RS
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 359 : 499 - 517
  • [10] PREDICTION OF PEPTIDE RETENTION TIMES IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .2. CORRELATION OF OBSERVED AND PREDICTED PEPTIDE RETENTION TIMES AND FACTORS INFLUENCING THE RETENTION TIMES OF PEPTIDES
    GUO, DC
    MANT, CT
    TANEJA, AK
    HODGES, RS