On-line concentration of acidic compounds by anion-selective exhaustive injection-sweeping-micellar electrokinetic chromatography

被引:57
作者
Zhu, LY [1 ]
Tu, CH [1 ]
Lee, HK [1 ]
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
关键词
D O I
10.1021/ac020381u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An easy, simple, and highly efficient on-line preconcentration method for acidic compounds in capillary electrophoresis was investigated. It combined two on-line concentration techniques, field-amplified sample injection (FASI) and sweeping. A low-pH (2.5) background electrolyte was used to suppress the electroosmotic flow (EOF), obviating the need of a coated capillary, as well as to neutralize the weakly acidic analytes. After injection of a plug of water inside the separation capillary, negative voltage was applied to initialize FASI for a much longer time than usual. The anions experienced a high electric field and moved quickly to the boundary of the water and the low-pH nonmicellar electrolyte. When the anions encountered the low-pH electrolyte, they were neutralized and a focused sample zone was formed. Then both inlet and outlet vials were changed to those containing the low-pH micellar background electrolyte. As negative voltage was applied, the anionic micelles moved into the capillary, and sweeping and separation began. The novelty in the present procedure is that a low-pH buffer is used to suppress the EOF and also the ionization of the analytes, without need of any other additives or use of a coated capillary. Ibis method afforded 100 000-fold improvement in peak heights for some phenoxy acidic herbicides. The detection limits for these compounds could be low as 100 pg/mL.
引用
收藏
页码:5820 / 5825
页数:6
相关论文
共 32 条
[1]   Large-volume stacking for quantitative analysis of anions in capillary electrophoresis .1. Large-volume stacking with polarity switching [J].
Albert, M ;
Debusschere, L ;
Demesmay, C ;
Rocca, JL .
JOURNAL OF CHROMATOGRAPHY A, 1997, 757 (1-2) :281-289
[2]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[3]  
Chien R. L., 1992, ANAL CHEM, V64, P489
[4]   SAMPLE STACKING OF AN EXTREMELY LARGE INJECTION VOLUME IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (09) :1046-1050
[5]   FIELD-AMPLIFIED POLARITY-SWITCHING SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :153-161
[6]   Analysis of DNA adducts in DNA hydrolysates by capillary zone electrophoresis and capillary zone electrophoresis electrospray mass spectrometry [J].
Deforce, DLD ;
Ryniers, FPK ;
VandenEeckhout, EG ;
Lemiere, F ;
Esmans, EL .
ANALYTICAL CHEMISTRY, 1996, 68 (20) :3575-3584
[7]   SAMPLE SELF-STACKING AND SAMPLE STACKING IN ZONE ELECTROPHORESIS WITH MAJOR SAMPLE COMPONENTS OF LIKE CHARGE - GENERAL-MODEL AND SCHEME OF POSSIBLE MODES [J].
GEBAUER, P ;
THORMANN, W ;
BOCEK, P .
ELECTROPHORESIS, 1995, 16 (11) :2039-2050
[8]   Large-volume sample stacking in acidic buffer for analysis of small organic and inorganic anions by capillary electrophoresis [J].
He, Y ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :995-1001
[9]   CAPILLARY ZONE ELECTROPHORESIS [J].
JORGENSON, JW ;
LUKACS, KD .
SCIENCE, 1983, 222 (4621) :266-272
[10]   ZONE ELECTROPHORESIS IN OPEN-TUBULAR GLASS-CAPILLARIES [J].
JORGENSON, JW ;
LUKACS, KD .
ANALYTICAL CHEMISTRY, 1981, 53 (08) :1298-1302