Acute myocardial infarction caused by thrombotic occlusion at a stent site two years after conventional stent implantation

被引:11
作者
Hayashi, T [1 ]
Kimura, A [1 ]
Ishikawa, K [1 ]
机构
[1] Kinki Univ, Sch Med, Dept Cardiol, Osakasayama 5898511, Japan
关键词
D O I
10.1136/hrt.2003.031419
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Two cases of acute myocardial infarction caused by thrombotic occlusion at the conventional stented site two years after stenting are described. Late thrombotic stent occlusion may be caused by atherosclerotic regression, sustained inflammatory reaction, and inhibition of proliferation of neointima. Cardiologists must be aware of the potential for late thrombosis following even conventional stent implantation.
引用
收藏
页数:3
相关论文
共 9 条
[1]   Remodeling of in-stent neointima, which became thinner and transparent over 3 years - Serial angiographic and angioscopic follow-up [J].
Asakura, M ;
Ueda, Y ;
Nanto, S ;
Hirayama, A ;
Adachi, T ;
Kitakaze, M ;
Hori, M ;
Kodama, K .
CIRCULATION, 1998, 97 (20) :2003-2006
[2]   Stent thrombosis - An issue revisited in a changing world [J].
Honda, Y ;
Fitzgerald, PJ .
CIRCULATION, 2003, 108 (01) :2-5
[3]   Histologic responses during in-stent neointimal regression in a porcine coronary model [J].
Hong, MK ;
Virmani, R ;
Kornowski, R ;
Jones, R ;
Kim, WH ;
Collins, S ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) :365A-366A
[4]   APOPTOSIS IN HUMAN ATHEROSCLEROSIS AND RESTENOSIS [J].
ISNER, JM ;
KEARNEY, M ;
BORTMAN, S ;
PASSERI, J .
CIRCULATION, 1995, 91 (11) :2703-2711
[5]   Three-year follow-up after implantation of metallic coronary-artery stents [J].
Kimura, T ;
Yokoi, H ;
Nakagawa, Y ;
Tamura, T ;
Kaburagi, S ;
Sawada, Y ;
Sato, Y ;
Yokoi, H ;
Hamasaki, N ;
Nosaka, H ;
Nobuyoshi, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (09) :561-566
[6]   Late acute thrombosis after paclitaxel eluting stent implantation [J].
Liistro, F ;
Colombo, A .
HEART, 2001, 86 (03) :262-264
[7]   Plaque sealing by coronary angioplasty [J].
Meier, B ;
Ramamurthy, S .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1995, 36 (04) :295-297
[8]  
Sabate M, 1999, Int J Cardiovasc Intervent, V2, P55
[9]   A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
SERRUYS, PW ;
DEJAEGERE, P ;
KIEMENEIJ, F ;
MACAYA, C ;
RUTSCH, W ;
HEYNDRICKX, G ;
EMANUELSSON, H ;
MARCO, J ;
LEGRAND, V ;
MATERNE, P ;
BELARDI, J ;
SIGWART, U ;
COLOMBO, A ;
GOY, JJ ;
VANDENHEUVEL, P ;
DELCAN, J ;
MOREL, MA .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :489-495