Fibrous composite materials in dentistry and orthopaedics: review and applications

被引:74
作者
Fujihara, K
Teo, K
Gopal, R
Loh, PL
Ganesh, VK
Ramakrishna, S
Foong, KWC
Chew, CL
机构
[1] Natl Univ Singapore, Biomat Lab, Div Bioengn, Singapore 117576, Singapore
[2] Natl Univ Singapore, Fac Dent, Singapore 119074, Singapore
[3] Natl Univ Singapore, Dept Engn Mech, Singapore 117576, Singapore
[4] Natl Univ Singapore, Nanosci & Nanotechnol Initiat, Singapore 117576, Singapore
关键词
textile composites; mechanical properties; finite element analysis; braiding;
D O I
10.1016/j.compscitech.2003.09.012
中图分类号
TB33 [复合材料];
学科分类号
摘要
In this report, the usage of fibrous composite materials in dentistry and orthopaedics is reviewed. Furthermore, the authors introduced functionally graded composite dental post, aesthetic composite archwires and brackets, and braided carbon/PEEK composite compression bone plate. Functionally graded composite dental post has continuously varied stiffness and this function successfully solved stress concentration at the root. Aesthetic composite archwires made of glass/epoxy unidirectional composite has targeted to obtain the highest bending performance by interface control. An epoxysilane coupling agent with 1.0 wt.% solvent showed the highest bending performance. Aesthetic composite bracket has fabricated by braided preform in order to reinforce tiewing slot where orthodontic force is applied through an archwire. Composite brackets have indicated around 43% mechanical resistance of stainless-steel bracket at tie-wing slot. Bending performance of the braided composite compression bone plates is investigated. The result indicates that the braided composite plate with 2.6 mm thickness can be suitable for forearm treatment whereas the braided composite plate of 3.2 mm thickness is applicable to femur or tibia fixation. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:775 / 788
页数:14
相关论文
共 95 条
[1]  
Aird J C, 1987, Br J Orthod, V14, P191
[2]  
Akay M, 1996, J BIOMED MATER RES, V31, P167
[3]   QUANTITATIVE HISTOLOGICAL EVALUATION OF EARLY FRACTURE HEALING OF CORTICAL BONES IMMOBILIZED BY STAINLESS-STEEL AND COMPOSITE PLATES [J].
AKESON, WH ;
WOO, SLY ;
COUTTS, RD ;
MATTHEWS, JV ;
GONSALVES, M ;
AMIEL, D .
CALCIFIED TISSUE RESEARCH, 1975, 19 (01) :27-37
[4]  
AKESON WH, 1980, CAN J SURG, V23, P235
[5]  
AkinNergiz N, 1996, EUR J ORTHODONT, V18, P295
[6]   CARBON-FIBER COMPOSITE BONE PLATES - DEVELOPMENT, EVALUATION AND EARLY CLINICAL-EXPERIENCE [J].
ALI, MS ;
FRENCH, TA ;
HASTINGS, GW ;
RAE, T ;
RUSHTON, N ;
ROSS, ERS ;
WYNNJONES, CH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04) :586-591
[7]   Torsional creep of polycarbonate orthodontic brackets [J].
Alkire, RG ;
Bagby, MD ;
Gladwin, MA ;
Kim, H .
DENTAL MATERIALS, 1997, 13 (01) :2-6
[8]  
[Anonymous], ORTHODONTIC TREATMEN
[9]   Stiffness, elastic limit, and strength of newer types of endodontic posts [J].
Asmussen, E ;
Peutzfeldt, A ;
Heitmann, T .
JOURNAL OF DENTISTRY, 1999, 27 (04) :275-278
[10]   Evaluation of frictional resistance in esthetic brackets [J].
Bazakidou, E ;
Nanda, RS ;
Duncanson, MG ;
Sinha, P .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1997, 112 (02) :138-144