Errors caused by combination of Di-4 ANEPPS and Fluo3/4 for simultaneous measurements of transmembrane potentials and intracellular calcium

被引:25
作者
Johnson, PL
Smith, W
Baynham, TC
Knisley, SB
机构
[1] Univ Alabama, Dept Biomed Engn, Sch Engn, Birmingham, AL 35294 USA
[2] Univ Alabama, Div Cardiovasc Dis, Sch Med, Birmingham, AL 35294 USA
关键词
Fluo-3; Fluo-4; Di-4; ANEPPS; transmembrane potentials; intracellular calcium concentration; cardiac tissue; fluorescence;
D O I
10.1114/1.198
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intracellular calcium concentration and transmembrane potentials are two important measurements used to study the mechanisms of cardiac activity. Fluorescent dyes have been used to measure these separately but not simultaneously in cardiac tissue. Fluo-3 and Fluo-4 (a recently improved version of Fluo-3) have been used to measure changes in intracellular calcium concentration and Di-4 ANEPPS has been used to measure transmembrane potentials. This paper addresses the feasibility of using these fluorescent dyes together in order to measure transmembrane potentials and intracellular calcium concentration simultaneously. For the dyes to be used simultaneously, their respective fluorescence spectra must be sufficiently separated in wavelength in order to allow them to be separated by optical filters or spectrographs. An apparatus was constructed to measure the dyes' spectra in a fluorescence imaging chamber as well as in an isolated perfused rabbit heart. The measured spectra were mathematically modeled in order to assess the spectral overlap error under different conditions. Error graphs were constructed which may help researchers select optical filters and dye concentrations that will result in an acceptable error. (C) 1999 Biomedical Engineering Society. [S0090-6964(99)01104-2].
引用
收藏
页码:563 / 571
页数:9
相关论文
共 10 条
[1]   DIGITAL-FILTERS FOR REAL-TIME ECG SIGNAL-PROCESSING USING MICROPROCESSORS [J].
AHLSTROM, ML ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (09) :708-713
[2]   TEMPERATURE-DEPENDENCE OF CA2+ WAVE PROPERTIES IN CARDIOMYOCYTES - IMPLICATIONS FOR THE MECHANISM OF AUTOCATALYTIC CA2+ RELEASE IN WAVE-PROPAGATION [J].
ENGEL, J ;
SOWERBY, AJ ;
FINCH, SAE ;
FECHNER, M ;
STIER, A .
BIOPHYSICAL JOURNAL, 1995, 68 (01) :40-45
[3]   SPECTRA, MEMBRANE-BINDING, AND POTENTIOMETRIC RESPONSES OF NEW CHARGE SHIFT PROBES [J].
FLUHLER, E ;
BURNHAM, VG ;
LOEW, LM .
BIOCHEMISTRY, 1985, 24 (21) :5749-5755
[4]   SPECTRA OF VOLTAGE-SENSITIVE FLUORESCENCE OF STYRYL-DYE IN NEURON MEMBRANE [J].
FROMHERZ, P ;
LAMBACHER, A .
BIOCHIMICA ET BIOPHYSICA ACTA, 1991, 1068 (02) :149-156
[5]   Measurement of membrane potential and [Ca2+](i) in cell ensembles: Application to the study of glutamate taste in mice [J].
Hayashi, Y ;
Zviman, MM ;
Brand, JG ;
Teeter, JH ;
Restrepo, D .
BIOPHYSICAL JOURNAL, 1996, 71 (02) :1057-1070
[6]   DESIGN OF A MULTIPOINT LASER SCANNED OPTICAL MONITOR OF CARDIAC ACTION-POTENTIAL PROPAGATION - APPLICATION TO MICROREENTRY IN GUINEA-PIG ATRIUM [J].
HILL, BC ;
COURTNEY, KR .
ANNALS OF BIOMEDICAL ENGINEERING, 1987, 15 (06) :567-577
[7]  
KNISLEY SB, 1995, P 17 ANN INT C ENG M
[8]   MODULATION OF CA2+ RELEASE IN CULTURED NEONATAL RAT CARDIAC MYOCYTES - INSIGHT FROM SUBCELLULAR RELEASE PATTERNS REVEALED BY CONFOCAL MICROSCOPY [J].
LIPP, P ;
NIGGLI, E .
CIRCULATION RESEARCH, 1994, 74 (05) :979-990
[9]  
MINTA A, 1989, J BIOL CHEM, V264, P8171
[10]  
SCHEAFFER RL, 1995, PROBABILITY STAT ENG