Reliability and accuracy of cone-beam computed tomography dental measurements

被引:310
作者
Baumgaertel, Sebastian [1 ]
Palomo, J. Martin [1 ]
Palomo, Leena [2 ]
Hans, Mark G. [1 ]
机构
[1] Case Western Reserve Univ, Sch Dent Med, Dept Orthodont, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Sch Dent Med, Dept Periodont, Cleveland, OH 44106 USA
关键词
TOOTH-SIZE;
D O I
10.1016/j.ajodo.2007.09.016
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Introduction: Dental measurements are an integral part of the orthodontic records necessary for proper diagnosis and treatment planning. In this study, we investigated the reliability and accuracy of dental measurements made on cone-beam computed tomography (CBCT) reconstructions. Methods: Thirty human skulls were scanned with dental CBCT, and 3-dimensional reconstructions of the dentitions were generated. Ten measurements (overbite, overjet, maxillary and mandibular intermolar and intercanine widths, arch length available, and arch length required) were made directly on the dentitions of the skulls with a high-precision digital caliper and on the digital reconstructions with commercially available software. Reliability and accuracy were assessed by using intraclass correlation and paired Student t tests. A P value of <= 0.05 was used to assign statistical significance. Results: Both the CBCT and the caliper measurements were highly reliable (r>0.90). The CBCT measurements tended to slightly underestimate the anatomic truth. This was statistically significant only for compounded measurements. Conclusions: Dental measurements from CBCT volumes can be used for quantitative analysis. With the CBCT images, we found a small systematic error, which became statistically significant only when combining several measurements. An adjustment for this error allows for improved accuracy. (Am J Orthod Dentofacial Orthop 2009; 136: 19-28)
引用
收藏
页码:19 / 25
页数:7
相关论文
共 33 条
[1]
Aboudara C A, 2003, Orthod Craniofac Res, V6 Suppl 1, P173, DOI 10.1034/j.1600-0544.2003.253.x
[2]
[Anonymous], INT COMM RAD PROT PU
[3]
Aranyarachkul P, 2005, INT J ORAL MAX IMPL, V20, P416
[4]
Bell A, 2003, J Orthod, V30, P219, DOI 10.1093/ortho/30.3.219
[5]
Construction and testing of a computer-based intraoral laser scanner for determining tooth positions [J].
Commer, P ;
Bourauel, C ;
Maier, K ;
Jäger, A .
MEDICAL ENGINEERING & PHYSICS, 2000, 22 (09) :625-635
[6]
DIAGNOSTIC-IMAGING IN DENTAL IMPLANTOLOGY [J].
FREDERIKSEN, NL .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1995, 80 (05) :540-554
[7]
Garib DG, 2005, ANGLE ORTHOD, V75, P548
[8]
Garino G.B., 2002, World J Orthod, V3, P250
[9]
NON-LINEAR PARTIAL VOLUME ARTIFACTS IN X-RAY COMPUTED-TOMOGRAPHY [J].
GLOVER, GH ;
PELC, NJ .
MEDICAL PHYSICS, 1980, 7 (03) :238-248
[10]
CONSISTENCY OF ORTHODONTIC TREATMENT DECISIONS RELATIVE TO DIAGNOSTIC RECORDS [J].
HAN, UK ;
VIG, KWL ;
WEINTRAUB, JA ;
VIG, PS ;
KOWALSKI, CJ .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1991, 100 (03) :212-219