Handling intrinsic non-linearity in near-infrared reflectance spectroscopy

被引:55
作者
Bertran, E
Blanco, M
Maspoch, S
Ortiz, MC
Sánchez, MS
Sarabia, LA
机构
[1] Univ Autonoma Barcelona, Unitat Quim Analit, Dept Quim, E-08193 Barcelona, Spain
[2] Univ Burgos, Fac Ciencias, Dept Matemat & Computac, E-09001 Burgos, Spain
[3] Univ Burgos, Fac Ciencias, Dept Quim, E-09001 Burgos, Spain
关键词
multivariate calibration; non-linearity; non-linear PLS; artificial neural networks; NIR spectroscopy; ampicillin trihydrate;
D O I
10.1016/S0169-7439(99)00043-X
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 [计算机科学与技术];
摘要
The relationship between absorption in the near-infrared (NIR) spectral region and the target analytical parameter is frequently of the non-linear type. The origin of the non-linearity can be widely varied and difficult to identify. In some cases, the relationship between absorption and the analytical parameter of interest is intrinsically non-linear owing to the very chemical nature of the sample or analyte concerned. In this work, various multivariate calibration procedures were tested with a view to overcoming intrinsic non-linearity in NIR reflectance. An approach to solving the problem is suggested, Calibration was done, after transformation of spectra, by using linear and non-linear techniques. The Linear calibration techniques used are partial least squares (PLS) regression (with and without variable selection), linear PLS with X projection (LP-PLS) and stepwise polynomial principal component (SWP-PC) regression. Non-linear calibration methods included polynomial PLS (PPLS) and artificial neural networks (ANNs). Results were compared on the basis of NIR spectra for ampicillin trihydrate samples, where the simultaneous presence of crystallization water and surface moisture gives rise to intrinsic non-linearity that affects the determination of the total water content in the sample. The best results were obtained by using the non-linear calibration techniques. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 29 条
[1]
TRANSFORMATIONS TO REDUCE THE EFFECT OF PARTICLE-SIZE IN NEAR-INFRARED SPECTRA [J].
AUCOTT, LS ;
GARTHWAITE, PH ;
BUCKLAND, ST .
ANALYST, 1988, 113 (12) :1849-1854
[2]
STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[3]
Near-infrared spectroscopy in the pharmaceutical industry [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
de la Pezuela, C .
ANALYST, 1998, 123 (08) :135R-150R
[4]
BLANCO M, UNPUB ANAL CHIM ACTA
[5]
OPTIMAL MINIMAL NEURAL INTERPRETATION OF SPECTRA [J].
BORGGAARD, C ;
THODBERG, HH .
ANALYTICAL CHEMISTRY, 1992, 64 (05) :545-551
[6]
CLEMENTI S, 1989, Journal of Chemometrics, V3, P499, DOI 10.1002/cem.1180030307
[7]
Dahm D.J., 1995, J NEAR INFRARED SPEC, V3, P53, DOI [10.1255/jnirs.55, DOI 10.1255/JNIRS.55]
[8]
Dhanoa M., 1994, Journal of Near Infrared Spectroscopy, V2, P43, DOI [10.1255/jnirs.30, DOI 10.1255/JNIRS.30]
[9]
Draper N. R., 1966, APPL REGRESSION ANAL
[10]
MULTIVARIATE ADAPTIVE REGRESSION SPLINES [J].
FRIEDMAN, JH .
ANNALS OF STATISTICS, 1991, 19 (01) :1-67