Redox polymer-based reagentless horseradish peroxidase biosensors Influence of the molecular structure of the polymer

被引:21
作者
Guschin, Dmitrii A.
Sultanov, Yusif M.
Sharif-Zade, Nigar F.
Aliyev, Elchin H.
Efendiev, Ayaz A.
Schuhmann, Wolfgang
机构
[1] Ruhr Univ Bochum, D-44780 Bochum, Germany
[2] Azerbaijan Natl Acad Sci, Inst Chem Problems, Baku, Azerbaijan
关键词
amperometric biosensor; horseradish peroxidase; Os-bis-N,N-(2,2 '-bipyridil)-dichloride; poly(4-vinylpyridine); poly(4-vinylpyridine-co-butyl methacrylate);
D O I
10.1016/j.electacta.2006.03.056
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Reagentless amperometric biosensors were prepared using a variety of nitrogen donor groups containing co-polymers. The polymers were coordinated with Os-bis-N,N-(2,2'-bipyridil)-dichloride via a ligand exchange reaction thus assuring an efficient electron-transfer pathway between the polymer-entrapped horseradish peroxidase and the electrode surface by means of a sequence of electron-hopping steps. The impact of structural features of the polymer such as spacer length between the Os-complex and the polymer backbone or the ratio of 4-vinylpyridine and butylmethacrylate in a co-polymer on the activity of the horseradish peroxidase biosensors was investigated. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5137 / 5142
页数:6
相关论文
共 18 条
[1]  
[Anonymous], REV MOL BIOTECHNOL, DOI DOI 10.1016/S1389-0352(01)00058-7
[2]   INTRAMOLECULAR ELECTRON-TRANSFER RATES IN FERROCENE-DERIVATIZED GLUCOSE-OXIDASE [J].
BADIA, A ;
CARLINI, R ;
FERNANDEZ, A ;
BATTAGLINI, F ;
MIKKELSEN, SR ;
ENGLISH, AM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (16) :7053-7060
[3]   Covalent attachment of osmium complexes to glucose oxidase and the application of the resulting modified enzyme in an enzyme switch responsive to glucose [J].
Battaglini, F ;
Bartlett, PN ;
Wang, JH .
ANALYTICAL CHEMISTRY, 2000, 72 (03) :502-509
[4]   An Os(byp)2ClPyCH2NHpoly(allylamine) hydrogel mediator for enzyme wiring at electrodes [J].
Danilowicz, C ;
Corton, E ;
Battaglini, F ;
Calvo, EJ .
ELECTROCHIMICA ACTA, 1998, 43 (23) :3525-3531
[5]   ELECTRICAL COMMUNICATION BETWEEN REDOX CENTERS OF GLUCOSE-OXIDASE AND ELECTRODES VIA ELECTROSTATICALLY AND COVALENTLY BOUND REDOX POLYMERS [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (06) :2357-2358
[6]   POLYACRYLAMIDE-BASED REDOX POLYMER FOR CONNECTING REDOX CENTERS OF ENZYMES TO ELECTRODES [J].
DELUMLEYWOODYEAR, T ;
ROCCA, P ;
LINDSAY, J ;
DROR, Y ;
FREEMAN, A ;
HELLER, AA .
ANALYTICAL CHEMISTRY, 1995, 67 (08) :1332-1338
[7]   Combinatorial microelectrochemistry:: Development and evaluation of an electrochemical robotic system -: art. no. 062204 [J].
Erichsen, T ;
Reiter, S ;
Ryabova, V ;
Bonsen, EM ;
Schuhmann, W ;
Märkle, W ;
Tittel, C ;
Jung, G ;
Speiser, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (06)
[8]   Modulating the redox properties of an osmium-containing metallopolymer through the supporting electrolyte and cross-linking [J].
Forster, RJ ;
Walsh, DA ;
Mano, N ;
Mao, F ;
Heller, A .
LANGMUIR, 2004, 20 (03) :862-868
[9]  
Habermüller K, 2000, ELECTROANAL, V12, P1383, DOI 10.1002/1521-4109(200011)12:17<1383::AID-ELAN1383>3.0.CO
[10]  
2-0