Environmental assessment of sewage disposal systems using 2D electrical-resistivity imaging and geochemical analysis: A case study from Ibadan, southwestern Nigeria

被引:26
作者
Amidu, S. A.
Olayinka, A. I.
机构
[1] Baylor Univ, Dept Geol, Waco, TX 76798 USA
[2] Univ Ibadan, Dept Geol, Ibadan, Nigeria
关键词
environmental assessment; 2D electrical-resistivity imaging; geochemical analysis; septic tank; Nigeria;
D O I
10.2113/gseegeosci.12.3.261
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A case study is presented of integrated use of 2D electrical-resistivity imaging and geochernical analysis in environmental impact assessment of sewage disposal systems. This involved geoenvironmental studies around a septic tank in Ibadan, southwestern Nigeria. The area is underlain by quartzites and quartz schists, whereas the weathered profile consists of sandy and silty clay with some gravel. Twenty-two multi-electrode resistivity profiling lines were taken using the Wenner array. The electrode spacing ranged from 1 to 8 m with a station interval of 1 m. Resistivity data analysis involved inversion using a rapid least-square technique and construction of iso-apparent resistivity contour maps. Four pits were dug, with two of the pits located on points of resistivity lows and the other two pits on points of high resistivity values. The pits were dug to a total depth of 2 m and soil samples collected from each pit at 0.5-, 1.0-, 1.5-, and 2.0-m depths. The samples were analyzed for conductivity and for Pb, Fe, Cu, Cr, and nitrate concentrations. The resistivity survey yielded low resistivity values at locations close to the septic tank and higher values farther from it. This agreed with the electrical conductivities measured for soil samples. Statistical analyses of the conductivity variation with distance from the septic tank yielded a negative correlation coefficient of between -0.92 and -0.52, indicating an inverse relationship between the two quantities. Similar relationships were established for analyzed chemical constituents. The environment is impacted by the septic system as shown by soil sampling and geophysical results. The results demonstrate that pollution mapping in a basement complex environment can be carried out using the approach described in this paper.
引用
收藏
页码:261 / 272
页数:12
相关论文
共 21 条
[1]   THE DEVELOPMENT OF CRYSTALLINE BASEMENT AQUIFERS IN A TROPICAL ENVIRONMENT [J].
ACWORTH, RI .
QUARTERLY JOURNAL OF ENGINEERING GEOLOGY, 1987, 20 (04) :265-272
[2]   Groundwater contamination in the basement-complex area of Ile-Ife, southwestern Nigeria: A case study using the electrical-resistivity geophysical method [J].
Adepelumi, AA ;
Ako, BD ;
Ajayi, TR .
HYDROGEOLOGY JOURNAL, 2001, 9 (06) :611-622
[3]  
[Anonymous], 2005, STANDARD METHODS EXA, V21
[4]   The electrical resistivity log as an aid in determining some reservoir characteristics [J].
Archie, GE .
TRANSACTIONS OF THE AMERICAN INSTITUTE OF MINING AND METALLURGICAL ENGINEERS, 1942, 146 :54-61
[5]   Mapping groundwater contamination using dc resistivity and VLF geophysical methods - A case study [J].
Benson, AK ;
Payne, KL ;
Stubben, MA .
GEOPHYSICS, 1997, 62 (01) :80-86
[6]  
BREMNER J. M., 1965, Monographs of the American Society of Agronomists, V9, P1179
[7]   Resolution of 2D Wenner resistivity imaging as assessed by numerical modelling [J].
Dahlin, T ;
Loke, MH .
JOURNAL OF APPLIED GEOPHYSICS, 1998, 38 (04) :237-249
[8]   OCCAM INVERSION TO GENERATE SMOOTH, 2-DIMENSIONAL MODELS FROM MAGNETOTELLURIC DATA [J].
DEGROOTHEDLIN, C ;
CONSTABLE, S .
GEOPHYSICS, 1990, 55 (12) :1613-1624
[9]  
FALCONE JD, 1987, PRINCIPLES PRACTICES
[10]  
KAEREY P, 1984, INTRO GEOPHYSICAL EX