Electrochemical determination of lead and glutathione in a plant cell culture

被引:69
作者
Vacek, J
Petrek, J
Kizek, R
Havel, L
Klejdus, B
Trnková, L
Jelen, F
机构
[1] Mendel Univ Brno, Dept Chem & Biochem, Brno 61300, Czech Republic
[2] Mendel Univ Brno, Dept Bot & Plant Physiol, Brno 61300, Czech Republic
[3] Masaryk Univ, Fac Sci, Dept Theoret & Phys Chem, Brno 61137, Czech Republic
[4] Acad Sci Czech Republ, Inst Biophys, Lab Biophys Chem & Mol Oncol, Brno 61265, Czech Republic
关键词
determination of lead; Pb(II)-EDTA; voltammetry; mercury electrode; Brdicka reaction; glutathione; metallothioneins;
D O I
10.1016/j.bioelechem.2003.08.007
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this work we established differential pulse anodic stripping voltammetry (DPASV) as the tool for analysis of lead in the plant cell culture. For the cultivation procedure, lead in Pb(II)-ethylenediaminetetraacetic acid (Pb-EDTA) chelate has been used. The detection limit of lead was found at 500 pM in phosphate buffer (pH 5.5), and 100 nM in prepared cells intracellular extract (20 pg Pb(II)/mg cells). For determination of cysteine-rich peptides, voltammetry in differential mode (DPV) in cobalt(Ill)-containing ammonia buffer (Brdicka reaction) was used. In this short communication, we present suitable voltammetric techniques for the physiological study of lead and thiols in plant cell culture. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:347 / 351
页数:5
相关论文
共 26 条
[1]  
[Anonymous], 1998, ATOMIC ABSORPTION SP
[2]   CATALYTIC CATHODIC STRIPPING VOLTAMMETRY AT A HANGING MERCURY DROP ELECTRODE OF GLUTATHIONE IN THE PRESENCE OF NICKEL ION [J].
BANICA, FG ;
FOGG, AG ;
MOREIRA, JC .
ANALYST, 1994, 119 (11) :2343-2349
[3]   Determination of glutathione-S-transferase traces in preparations of p53 C-terminal domain (aa320-393) [J].
Brázdová, M ;
Kizek, R ;
Havran, L ;
Palecek, E .
BIOELECTROCHEMISTRY, 2002, 55 (1-2) :115-118
[4]  
Brdicka R., 1933, COLLECT CZECH CHEM C, V5, P112, DOI [DOI 10.1135/CCCC19330112, 10.1135/cccc19330112]
[5]   APPLICATION HINTS FOR SAVITZKY-GOLAY DIGITAL SMOOTHING FILTERS [J].
BROMBA, MUA ;
ZIEGLER, H .
ANALYTICAL CHEMISTRY, 1981, 53 (11) :1583-1586
[6]   DETERMINATION OF GLUTATHIONE IN BIOLOGICAL-MATERIAL BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
BUCHBERGER, W ;
WINSAUER, K .
ANALYTICA CHIMICA ACTA, 1987, 196 :251-254
[7]   Phytochelatins and metallothioneins: Roles in heavy metal detoxification and homeostasis [J].
Cobbett, C ;
Goldsbrough, P .
ANNUAL REVIEW OF PLANT BIOLOGY, 2002, 53 :159-182
[8]   Differential pulse polarographic study of the Pb(II) complexation by glutathione [J].
Cruz, BH ;
Díaz-Cruz, JM ;
Díaz-Cruz, MS ;
Ariño, C ;
Esteban, M ;
Tauler, R .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 516 (1-2) :110-118
[9]   Recent developments in quantification methods for metallothionein [J].
Dabrio, M ;
Rodríguez, AR ;
Bordin, G ;
Bebianno, MJ ;
De Ley, M ;
Sestaková, I ;
Vasák, M ;
Nordberg, M .
JOURNAL OF INORGANIC BIOCHEMISTRY, 2002, 88 (02) :123-134
[10]   Differential pulse cathodic stripping adsorption voltammetric determination of trace amounts of lead using factorial design for optimization [J].
Ensafi, AA ;
Khayamian, T ;
Atabati, M .
TALANTA, 2003, 59 (04) :727-733