Multidirectional flexibility analysis of anterior and posterior lumbar artificial disc reconstruction: in vitro human cadaveric spine model

被引:26
作者
Kotani, Yoshihisa
Cunningham, Bryan W.
Abumi, Kuniyoshi
Dmitriev, Anton E.
Hu, Niabin
Ito, Manabu
Shikinami, Yasuo
McAfee, Paul C.
Minami, Akio
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Orthopaed Surg, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Union Mem Hosp, Orthopaed Res Lab, Baltimore, MD 21218 USA
[3] Takiron Co Ltd, Div Med, Chuo Ku, Osaka 5410052, Japan
关键词
artificial intervertebral disc; lumbar spine; biomechanics;
D O I
10.1007/s00586-006-0086-z
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The in vitro multidirectional flexibility analysis was conducted to investigate the initial biomechanical effect of biomimetic artificial intervertebral disc replacement from either anterior or posterior approach in a cadaveric lumbosacral spine model. Two designs of anterior total and posterior subtotal artificial discs were developed using bioactive three-dimensional fabric and bioresorbable hydroxyapatite/poly-l-lactide material (3DF disc). Both models were designed to obtain the stable interface bonding to vertebral endplates with maximum surface area occupation. Using seven cadaveric lumbosacral spines, the following three anterior reconstruction methods were sequentially performed at L4-5 level: anterior 3DF disc replacement; anterior BAK cages (BAK); and posterior pedicle screw fixation and anterior BAK cages combined (BAK + PS). The L2-3 level received two methods of posterior reconstructions: subtotal 3DF disc replacement (two implants), and posterior interbody cages and pedicle screw fixation (PLIF). Six unconstrained pure moments were applied and three-dimensional segmental motions were measured with an optoelectronic motion measurement system. The center of rotation (COR) calculation was conducted radiographically using flexion-extension films. Both anterior and posterior 3DF replacements statistically demonstrated equivalent range of motions (ROMs) in all loading modes compared to intact segment. Anterior BAK, BAK + PS, and PLIF demonstrated significantly lower ROMs when compared to intact and 3DF groups (P < 0.05). The 3DF reconstruction tended to realign the COR to the posterior third or surrounding position at the operative disc level. The stand-alone lumbar 3DF disc replacement demonstrated biomechanical characteristics nearly equivalent to the intact spinal segments even through anterior or posterior approach in vitro, suggesting an excellent clinical potential.
引用
收藏
页码:1511 / 1520
页数:10
相关论文
共 37 条
[1]
Wear analysis of the Bryan Cervical Disc prosthesis [J].
Anderson, PA ;
Rouleau, JP ;
Bryan, VE ;
Carlson, CS .
SPINE, 2003, 28 (20) :S186-S194
[2]
[Anonymous], 1990, CLIN BIOMECH
[3]
The artificial disc: Theory, design and materials [J].
Bao, QB ;
McCullen, GM ;
Higham, PA ;
Dumbleton, JH ;
Yuan, HA .
BIOMATERIALS, 1996, 17 (12) :1157-1167
[4]
BAO QB, 2002, CLIN ORTHOP RELAT R, V394, P139
[5]
Cervical motion segment replacement [J].
Bryan, VE .
EUROPEAN SPINE JOURNAL, 2002, 11 (Suppl 2) :S92-S97
[6]
BIOMECHANICS OF THE SB CHARITE LUMBAR INTERVERTEBRAL-DISK ENDOPROSTHESIS [J].
BUTTNERJANZ, K ;
SCHELLNACK, K ;
ZIPPEL, H .
INTERNATIONAL ORTHOPAEDICS, 1989, 13 (03) :173-176
[7]
Results of disc prosthesis after a minimum follow-up period of 2 years [J].
Cinotti, G ;
David, T ;
Postacchini, F .
SPINE, 1996, 21 (08) :995-1000
[8]
Surgical experience with an implanted artificial cervical joint [J].
Cummins, BH ;
Robertson, JT ;
Gill, SS .
JOURNAL OF NEUROSURGERY, 1998, 88 (06) :943-948
[9]
Biomechanical evaluation of total disc replacement arthroplasty:: An in vitro human cadaveric model [J].
Cunningham, BW ;
Gordon, JD ;
Dmitriev, AE ;
Hu, NB ;
McAfee, PC .
SPINE, 2003, 28 (20) :S110-S117
[10]
Total disc replacement arthroplasty using the AcroFlex lumbar disc: a non-human primate model [J].
Cunningham, BW ;
Lowery, GL ;
Serhan, HA ;
Dmitriev, AE ;
Orbegoso, CM ;
McAfee, PC ;
Fraser, RD ;
Ross, RE ;
Kulkarni, SS .
EUROPEAN SPINE JOURNAL, 2002, 11 (Suppl 2) :S115-S123