Direct quantification of ethyl glucuronide in clinical urine samples by liquid chromatography-mass spectrometry

被引:99
作者
Stephanson, N
Dahl, H
Helander, A
Beck, O
机构
[1] Karolinska Hosp & Inst, Dept Med, Div Clin Pharmacol, Stockholm, Sweden
[2] Karolinska Hosp & Inst, Dept Clin Neurosci, Alcohol Lab, Stockholm, Sweden
关键词
ethyl glucuronide; urine; ethanol metabolism; liquid chromatography; mass spectrometry;
D O I
10.1097/00007691-200210000-00011
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Ethyl glucuronide is a minor metabolite of ethanol, and its presence in urine can be used as a laboratory test to detect recent alcohol intake, even for some time after the ethanol is no longer measurable. A simple analytical procedure was developed based on direct injection of urine diluted with a deuterated internal standard into an electrospray liquid chromatographic-mass spectrometric (LC-MS) system. A novel LC system using a porous graphite column (Hypercarb) enabled an isocratic elution with retention times of 5-6 minutes. The intra- and inter-assay coefficients of variation were 2-12%, and the measuring range was 0.1-1,500 mg/L (0.45-6,750 mumol/L). Ethyl glucuronide was found to be stable in urine for more than 4 days at room temperature, and no artifactual formation was observed on storage of urine samples fortified with 1% ethanol. Ethyl glucuronide was not detected in urine samples collected after abstinence from alcohol. Intake of a very low amount (7 g) of ethanol produced ethyl glucuronide values up to 8.4 mg/L after 4 hours and was still detectable at 6 hours. When the method was applied for routine screening of 252 clinical urine samples (range, 0-1,240 mg/L), it fulfilled the need for a simple and reliable assay to be used in the evaluation of urinary ethyl glucuronide as a routine test of recent alcohol intake.
引用
收藏
页码:645 / 651
页数:7
相关论文
共 22 条
[1]   Determination of ethyl glucuronide in hair samples [J].
Alt, A ;
Janda, I ;
Seidl, S ;
Wurst, FM .
ALCOHOL AND ALCOHOLISM, 2000, 35 (03) :313-314
[2]   POROUS GRAPHITIC CARBON SHOWS PROMISE FOR THE RAPID CHROMATOGRAPHIC ANALYSIS OF POLAR DRUG METABOLITES [J].
AYRTON, J ;
EVANS, MB ;
HARRIS, AJ ;
PLUMB, RS .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 667 (01) :173-178
[3]   The use of a porous graphitic carbon column for desalting hydrophilic peptides prior to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [J].
Chin, ET ;
Papac, DI .
ANALYTICAL BIOCHEMISTRY, 1999, 273 (02) :179-185
[4]   Comparison of urinary excretion characteristics of ethanol and ethyl glucuronide [J].
Dahl, H ;
Stephanson, N ;
Beck, O ;
Helander, A .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2002, 26 (04) :201-204
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF OLIGOSACCHARIDE ALDITOLS AND GLYCOPEPTIDES ON A GRAPHITIZED CARBON COLUMN [J].
DAVIES, M ;
SMITH, KD ;
HARBIN, AM ;
HOUNSELL, EF .
JOURNAL OF CHROMATOGRAPHY, 1992, 609 (1-2) :125-131
[6]  
Helander A, 2001, ALCOHOL IN HEALTH AND DISEASE, P177
[7]  
JAAKONMAKI P. I., 1967, EUR J PHARMACOL, V1, P63, DOI 10.1016/0014-2999(67)90067-2
[8]   Improvement of ethyl glucuronide determination in human urine and serum samples by solid-phase extraction [J].
Janda, I ;
Alt, A .
JOURNAL OF CHROMATOGRAPHY B, 2001, 758 (02) :229-234
[9]   EXCRETION OF ALCOHOL IN URINE AND DIURESIS IN HEALTHY-MEN IN RELATION TO THEIR AGE, THE DOSE ADMINISTERED AND THE TIME AFTER DRINKING [J].
JONES, AW .
FORENSIC SCIENCE INTERNATIONAL, 1990, 45 (03) :217-224
[10]   Effect of high-fat, high-protein, and high-carbohydrate meals on the pharmacokinetics of a small dose of ethanol [J].
Jones, AW ;
Jönsson, KÅ ;
Kechagias, S .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1997, 44 (06) :521-526