Removal of COD from landfill leachate by electro-Fenton method

被引:263
作者
Zhang, Hui [1 ]
Zhang, Daobin [1 ]
Zhou, Jiayong [1 ]
机构
[1] Wuhan Univ, Dept Environm Engn, Wuhan 430079, Peoples R China
关键词
landfill leachate; Fenton's reagent; electro-Fenton; chemical oxidation;
D O I
10.1016/j.jhazmat.2005.11.025
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The treatment of landfill leachate by electro-Fenton (E-Fenton) method was carried out in a batch electrolytic reactor. The effect of operating conditions such as reaction time, the distance between the electrodes, electrical current, H2O2 to Fe(II) molar ratio, Fenton's reagent dosage and H2O2 feeding mode on the efficacy of E-Fenton process was investigated. It is demonstrated that E-Fenton method can effectively degrade leachate organics. The process was very fast in the first 30 min and then slowed down till it was complete in 75 min. There exists an optimal distance range between the electrodes so that an over 7% higher chemical oxygen demand (COD) removal was achieved than the electrodes positioned beyond this range. COD removal efficiency increased with the increasing current, but further increase of current would reduce the removal efficiency. Organic removal increased as Fenton's reagent dosage increased at the fixed H2O2 to Fe(II) molar ratio. COD removal was only 65% when hydrogen peroxide alone was applied to the electrolytic reactor, and the presence of ferrous ion greatly improved COD removal. COD removal efficiency increased with the increase of ferrous ion dosage at the fixed hydrogen peroxide dose and reached highest at the 0.038 mol/L of ferrous ion concentration. COD removal would decrease when ferrous ion concentration was higher than 0.038 mol/L. The stepwise or continuous addition of hydrogen peroxide was more effective than the addition of hydrogen peroxide in a single step. E-Fenton method showed the synergetic effect for COD removal as it achieved higher COD removal than the total COD removal by electrochemical method and Fenton's reagent. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:106 / 111
页数:6
相关论文
共 41 条
[1]  
[Anonymous], RUSS CHEM REV
[2]  
*APHA AWWA WPCF, 1992, STAND METH EX WAT WA
[3]   HYDROGEN PEROXIDE CATALYTIC OXIDATION OF REFRACTORY ORGANICS IN MUNICIPAL WASTE WATERS [J].
BISHOP, DF ;
STERN, G ;
FLEISCHMAN, M ;
MARSHALL, LS .
INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1968, 7 (01) :110-+
[4]   Anodic oxidation, electro-Fenton and photoelectro-Fenton treatments of 2,4,5-trichlorophenoxyacetic acid [J].
Boye, B ;
Dieng, MM ;
Brillas, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2003, 557 :135-146
[5]   Degradation of herbicide 4-chlorophenoxyacetic acid by advanced electrochemical oxidation methods [J].
Boye, B ;
Dieng, MM ;
Brillas, E .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (13) :3030-3035
[6]   Electrochemical destruction of chlorophenoxy herbicides by anodic oxidation and electro-Fenton using a boron-doped diamond electrode [J].
Brillas, E ;
Boye, B ;
Sirés, I ;
Garrido, JA ;
Rodríguez, RM ;
Arias, C ;
Cabot, PL ;
Comninellis, C .
ELECTROCHIMICA ACTA, 2004, 49 (25) :4487-4496
[7]   Mineralization of herbicide 3,6-dichloro-2-methoxybenzoic acid in aqueous medium by anodic oxidation, electro-Fenton and photoelectro-Fenton [J].
Brillas, E ;
Baños, MA ;
Garrido, JA .
ELECTROCHIMICA ACTA, 2003, 48 (12) :1697-1705
[8]   Mineralization of 2,4-D by advanced electrochemical oxidation processes [J].
Brillas, E ;
Calpe, JC ;
Casado, J .
WATER RESEARCH, 2000, 34 (08) :2253-2262
[9]   Aniline degradation by Electro-Fenton® and peroxi-coagulation processes using a flow reactor for wastewater treatment [J].
Brillas, E ;
Casado, J .
CHEMOSPHERE, 2002, 47 (03) :241-248
[10]   CRITICAL-REVIEW OF RATE CONSTANTS FOR REACTIONS OF HYDRATED ELECTRONS, HYDROGEN-ATOMS AND HYDROXYL RADICALS (.OH/.O-) IN AQUEOUS-SOLUTION [J].
BUXTON, GV ;
GREENSTOCK, CL ;
HELMAN, WP ;
ROSS, AB .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1988, 17 (02) :513-886