Parathyroid glands:: Combination of 99mTc MIBI scintigraphy and US for demonstration of parathyroid glands and nodules

被引:146
作者
De Feo, ML
Colagrande, S
Biagini, C
Tonarelli, A
Bisi, G
Vaggelli, L
Borrelli, D
Cicchi, P
Tonelli, F
Amorosi, A
Serio, M
Brandi, ML
机构
[1] Univ Florence, Dept Clin Physiopathol, Endocrine Unit, I-50139 Florence, Italy
[2] Univ Florence, Dept Clin Physiopathol, Radiol Unit, I-50139 Florence, Italy
[3] Univ Florence, Dept Clin Physiopathol, Nucl Med Unit, I-50139 Florence, Italy
[4] Univ Florence, Anat Pathol Unit, I-50139 Florence, Italy
关键词
parathyroid; CT; hyperparathyroidism; MR; neoplasms; radionuclide studies; US;
D O I
10.1148/radiology.214.2.r00fe04393
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the appropriate choice of imaging techniques for localization of nodular lesions of parathyroid glands. MATERIALS AND METHODS: First, computed tomographic (CT), magnetic resonance (MR), ultrasonographic (US), and technetium 99m methoxyisobutyl-isonitrile (MIBI) scintigraphic images in 49 patients with primary hyperparathyroidism were retrospectively evaluated. A single-blind, prospective study that included 16 patients with primary hyperparathyroidism was then conducted. MR, US, scintigraphic, and color Doppler US images of the neck were obtained and analyzed. RESULTS: in the retrospective study, CT, MR imaging, and US had low sensitivity (13%, 17%, and 27,respectively) and specificity (39%, 65%, and 65%, respectively). Scintigraphy had 57% sensitivity and 85% specificity. In the prospective study, the use of latest-generation MR and US equipment and the participation of experienced operators led to improved sensitivity and specificity for these techniques. The combination of US and scintigraphy resulted in improved sensitivity (96%), specificity (83%), and positive and negative predictive values (88% and 94%, respectively), relative to the results obtained with either method alone. Doppler US was of little help in the setting of small glands. CONCLUSIONS: The combination of Tc-99m MIBI scintigraphy and US performed by well-trained operators with up-to-date instruments appeared to be the best diagnostic tool for the preoperative diagnosis of parathyroid disease.
引用
收藏
页码:393 / 402
页数:10
相关论文
共 25 条
[1]  
AKERSTROM G, 1984, SURGERY, V95, P14
[2]   PROSPECTIVE COMPARISON OF RADIONUCLIDE, ULTRASOUND, AND COMPUTED-TOMOGRAPHY IN THE PREOPERATIVE LOCALIZATION OF PARATHYROID-GLANDS [J].
CARMALT, HL ;
GILLETT, DJ ;
CHU, J ;
EVANS, RA ;
KOS, S .
WORLD JOURNAL OF SURGERY, 1988, 12 (06) :830-834
[3]   PROSPECTIVE COMPARISON OF TECHNETIUM-99M-SESTAMIBI I-123 RADIONUCLIDE SCAN VERSUS HIGH-RESOLUTION ULTRASONOGRAPHY FOR THE PREOPERATIVE LOCALIZATION OF ABNORMAL PARATHYROID-GLANDS IN PATIENTS WITH PREVIOUSLY UNOPERATED PRIMARY HYPERPARATHYROIDISM [J].
CASAS, AT ;
BURKE, GJ ;
SATHYANARAYANA ;
MANSBERGER, AR ;
WEI, JP .
AMERICAN JOURNAL OF SURGERY, 1993, 166 (04) :369-373
[4]  
Doppman John L., 1994, P553
[5]  
DUH QY, 1987, ACTA CHIR SCAND, V153, P241
[6]  
FLEISS JL, 1981, STATISTICAL METHODS, P56
[7]  
GEATTI O, 1994, EUR J NUCL MED, V21, P17
[8]   PARATHYROID IMAGING - COMPARISON OF DOUBLE-TRACER (TL-201, TC-99M) SCINTIGRAPHY AND HIGH-RESOLUTION ULTRASOUND [J].
GOODING, GAW ;
OKERLUND, MD ;
STARK, DD ;
CLARK, OH .
RADIOLOGY, 1986, 161 (01) :57-64
[9]   FURTHER EVIDENCE AGAINST THE ROUTINE USE OF PARATHYROID ULTRASONOGRAPHY PRIOR TO INITIAL NECK EXPLORATION FOR HYPERPARATHYROIDISM [J].
HASSELGREN, PO ;
FIDLER, JP .
AMERICAN JOURNAL OF SURGERY, 1992, 164 (04) :337-340
[10]  
Heath H 3rd, 1991, J Bone Miner Res, V6 Suppl 2, pS63