Galvanic corrosion behavior of titanium implants coupled to dental alloys

被引:80
作者
Cortada, M
Giner, LL
Costa, S
Gil, FJ
Rodríguez, D
Planell, JA
机构
[1] Univ Int Catalunya, Fac Ciencias Salud, Barcelona, Spain
[2] Univ Politecn Cataluna, ETS Engn Ind Barcelona, Dept Ciencia Mat & Ingn Met, E-08028 Barcelona, Spain
关键词
D O I
10.1023/A:1008905229522
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The corrosion of five materials for implant suprastructures (cast-titanium, machined-titanium, gold alloy, silver-palladium alloy and chromium-nickel alloy), was investigated in vitro, the materials being galvanically coupled to a titanium implant. Various electrochemical parameters E(CORR), i(CORR) Evans diagrams, polarization resistance and Tafel slopes) were analyzed. The microstructure of the different dental materials was observed before and after corrosion processes by optical and electron microscopy. Besides, the metallic ions released in the saliva environment were quantified during the corrosion process by means of inductively coupled plasma-mass spectrometry technique (ICP-MS). The cast and machined titanium had the most passive current density at a given potential and chromium-nickel alloy had the most active critical current density values. The high gold content alloys have excellent resistance corrosion, although this decreases when the gold content is lower in the alloy. The palladium alloy had a low critical current density due to the presence of gallium in this composition but a selective dissolution of copper-rich phases was observed through energy dispersive X-ray analysis. (C) 2000 Kluwer Academic Publishers.
引用
收藏
页码:287 / 293
页数:7
相关论文
共 25 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]  
BABOIAN R, 1976, ASTM STP, V576, P6
[3]  
Branemark P.-I., 1977, SCAND J PLAST RECO S, V2, P16
[4]  
Branemark PI, 1982, ADV BIOMATER, V4, P133
[5]   STUDY OF ELECTROCHEMICAL BEHAVIOR OF GOLD DENTAL ALLOYS [J].
BRUGIRARD, J ;
BARGAIN, R ;
DUPUY, JC ;
MAZILLE, H ;
MONNIER, G .
JOURNAL OF DENTAL RESEARCH, 1973, 52 (04) :828-836
[6]  
Brugirard J, 1970, ETUDE COMPORTAMENT E, P62
[7]   METAL RELEASE FROM DENTAL BIOMATERIALS [J].
BRUNE, D .
BIOMATERIALS, 1986, 7 (03) :163-175
[8]  
CANAY S, 1992, DENT RES, V23, P279
[9]   A CLINICAL-EVALUATION OF FIXED-BRIDGE RESTORATIONS SUPPORTED BY THE COMBINATION OF TEETH AND OSSEOINTEGRATED TITANIUM IMPLANTS [J].
ERICSSON, I ;
LEKHOLM, U ;
BRANEMARK, PI ;
LINDHE, J ;
GLANTZ, PO ;
NYMAN, S .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1986, 13 (04) :307-312
[10]   IN-VITRO CORROSION MEASUREMENTS OF DENTAL ALLOYS [J].
GEISGERSTORFER, J .