Primary total hip arthroplasty with a porous-coated acetabular component - A concise follow-up of a previous report

被引:34
作者
Della Valle, CJ [1 ]
Berger, RA [1 ]
Shott, S [1 ]
Rosenberg, AG [1 ]
Jacobs, JJ [1 ]
Quigley, L [1 ]
Galante, JO [1 ]
机构
[1] Rush Univ, Med Ctr, Dept Orthopaed Surg, Chicago, IL 60612 USA
关键词
D O I
10.2106/00004623-200406000-00014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We previously reported the seven-to-ten-year results of the use of a porous-coated acetabular metal shell in a consecutive series of 204 primary total hip arthroplasties. In the present study, we evaluated the longerterm outcomes of these arthroplasties, at fifteen to eighteen years. One hundred and thirty-six (96%) of the 142 hips available for study retained the original acetabular metal shell. Three of the 142 metal shells failed secondary to aseptic loosening. Ten hips (7%) required a change of the modular acetabular liner because of excessive wear or for the treatment of osteolysis. The fifteen-year rate of survival of the metal shell, with failure defined as revision because of loosening or radiographic evidence of loosening, was 99%. The rate of survival of cementless acetabular reconstructions was excellent at fifteen years, although osteolysis and reoperations were noted to occur much more frequently as the duration of follow-up increased. The majority of the complications were related to wear of the polyethylene liner. Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:1217 / 1222
页数:6
相关论文
共 6 条
[1]
Second-generation cementless total hip arthroplasty - Eight to eleven-year results [J].
Archibeck, MJ ;
Berger, RA ;
Jacobs, JJ ;
Quigley, LR ;
Gitelis, S ;
Rosenberg, AG ;
Galante, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (11) :1666-1673
[3]
NONPARAMETRIC-ESTIMATION FROM INCOMPLETE OBSERVATIONS [J].
KAPLAN, EL ;
MEIER, P .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1958, 53 (282) :457-481
[4]
PRIMARY TOTAL HIP RECONSTRUCTION WITH A TITANIUM FIBER-COATED PROSTHESIS INSERTED WITHOUT CEMENT [J].
MARTELL, JM ;
PIERSON, RH ;
JACOBS, JJ ;
ROSENBERG, AG ;
MALEY, M ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (04) :554-571
[5]
Primary total hip arthroplasty with a porous-coated acetabular component - Seven-to-ten-year results [J].
Tompkins, GS ;
Jacobs, JJ ;
Kull, LR ;
Rosenberg, AG ;
Galante, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (02) :169-176
[6]
Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: Average ten-year follow-up [J].
Udomkiat, P ;
Dorr, LD ;
Wan, ZN .