Design and hydrodynamic evaluation of a novel pulsatile bioreactor for biologically active heart valves

被引:89
作者
Hildebrand, DK
Wu, ZJJ
Mayer, JE
Sacks, MS
机构
[1] Univ Pittsburgh, McGowan Inst Regenerat Med, Engineered Tissue Mech Lab, Pittsburgh, PA 15219 USA
[2] Univ Pittsburgh, Dept Bioengn, Engineered Tissue Mech Lab, Pittsburgh, PA USA
[3] Harvard Univ, Sch Med, Childrens Hosp Boston, Dept Cardiovasc Surg, Boston, MA USA
关键词
tissue engineering; heart valves; bioreactor; mock loop; pulse duplicator; cardiovascular; windkessel;
D O I
10.1114/B:ABME.0000036640.11387.4b
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Biologically active heart valves (tissue engineered and recellularized tissue-derived heart valves) have the potential to offer enhanced function when compared to current replacement value therapies since they can possibly remodel, and grow to meet the needs of the patient, and not require chronic medication. However, this technology is still in its infancy and many fundamental questions remain as to how these valves will function in vivo. It has been shown that exposing biologically active tissue constructs to pulsatile pressures and flows during in vitro culture produces enhanced extracellular matrix protein expression and cellularity, although the ideal hydrodynamic conditioning regime is as yet unknown. More over, in vitro organ-level studies of living heart valves aimed at studying the remodeling processes require environments that can accurately reproduce in vivo hemodynamics under sterile conditions. To this end, we have developed a system to study the effects of subjecting biologically active heart valves to highly controlled pulsatile pressure and flow waveforms under sterile conditions. The device fits inside a standard incubator and utilizes a computer-controlled closed loop feedback system to provide a high degree of control. The mean pressure, mean flow rate, driving frequency, and shape of the pulsatile pressure waveform can be changed automatically in order to simulate both physiologic and nonphysiologic hemodynamic conditions. Extensive testing and evaluation demonstrated the device's ability to subject a biologically active heart valve to highly controlled pulsatile waveforms that can be modulated during the course of sterile incubation.
引用
收藏
页码:1039 / 1049
页数:11
相关论文
共 30 条
[1]
SIMULATION INVITRO OF PULSATILE VASCULAR HEMODYNAMICS USING A CAD CAM-DESIGNED CAM DISK AND ROLLER FOLLOWER [J].
BRANT, AM ;
CHMIELEWSKI, JF ;
HUNG, TK ;
BOROVETZ, HS .
ARTIFICIAL ORGANS, 1986, 10 (05) :419-421
[2]
Chakravarti L., 1967, HDB METHODS APPL STA
[3]
D'Souza SS, 2003, J HEART VALVE DIS, V12, P110
[4]
DESIGN OF A HYDRAULIC ANALOG OF CIRCULATORY-SYSTEM FOR EVALUATING ARTIFICIAL HEARTS [J].
DONOVAN, FM .
BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1975, 3 (04) :439-449
[5]
Design of a new pulsatile bioreactor for tissue engineered aortic heart valve formation [J].
Dumont, K ;
Yperman, J ;
Verbeken, E ;
Segers, P ;
Meuris, B ;
Vandenberghe, S ;
Flameng, W ;
Verdonck, PR .
ARTIFICIAL ORGANS, 2002, 26 (08) :710-714
[6]
*FDA, 1994, REPL HEART VALV GUID
[7]
MOCK CIRCULATORY-SYSTEM FOR IN-VITRO REPRODUCTION OF THE LEFT-VENTRICLE, THE ARTERIAL TREE AND THEIR INTERACTION WITH A LEFT-VENTRICULAR ASSIST DEVICE [J].
FERRARI, G ;
DELAZZARI, C ;
MIMMO, R ;
AMBROSI, D ;
TOSTI, G .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1994, 18 (03) :87-95
[8]
Hoerstrup SP, 2000, CIRCULATION, V102, P44
[9]
Tissue engineering of small caliber vascular grafts [J].
Hoerstrup, SP ;
Zünd, G ;
Sodian, R ;
Schnell, AM ;
Grünenfelder, J ;
Turina, MI .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 20 (01) :164-169
[10]
New pulsatile bioreactor for in vitro formation of tissue engineered heart valves [J].
Hoerstrup, SP ;
Sodian, R ;
Sperling, JS ;
Vacanti, JP ;
Mayer, JE .
TISSUE ENGINEERING, 2000, 6 (01) :75-79