An inexpensive dual-chamber particle monitor: Laboratory characterization

被引:44
作者
Edwards, Rufus
Smith, Kirk R.
Kirby, Brent
Allen, Tracy
Litton, Charles D.
Hering, Susanne
机构
[1] Univ Calif Irvine, Sch Social Ecol, Irvine, CA USA
[2] Univ Calif Berkeley, Sch Publ Hlth, Berkeley, CA 94720 USA
[3] Princeton Univ, Dept Chem, Princeton, NJ 08544 USA
[4] Aerosol Dynam, Berkeley, CA USA
[5] EME, Berkeley, CA USA
[6] Ctr Dis Control & Prevent, NIOSH, Pittsburgh Res Lab, Pittsburgh, PA USA
关键词
D O I
10.1080/10473289.2006.10464491
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In developing countries, high levels of particle pollution from the use of coal and biomass fuels for household cooking and heating are a major cause of ill health and premature mortality. The cost and complexity of existing monitoring equipment, combined with the need to sample many locations, make routine quantification of household particle pollution levels difficult. Recent advances in technology, however, have enabled the development of a small, portable, data-logging particle monitor modified from commercial smoke alarm technology that can meet the needs of surveys in the developing world at reasonable cost. Laboratory comparisons of a prototype particle monitor developed at the University of California at Berkeley (UCB) with gravimetric filters, a tapered element oscillating microbalance, and a TSI DustTrak to quantify the UCB particle monitor response as a function of both concentration and particle size and to examine sensor response in relation to changes in temperature, relative humidity, and elevation are presented here. UCB particle monitors showed good linearity in response to different concentrations of laboratory-generated oleic acid aerosols with a coarse (mass median diameter, 2.1 mu m) and fine (mass median diameter, 0.27-0.42 mu m) size distributions (average r(2) = 0.997 +/- 0.005). The photoelectric and ionization chamber showed a wide range of responses based on particle size and, thus, require calibration with the aerosol of interest. The ionization chamber was five times more sensitive to fine rather than coarse particles, whereas the photoelectric chamber was five times more sensitive to coarse than fine. The ratio of the response between the two sensors has the potential for mass calibration of individual data points based on estimated parameters of the size distribution. The results demonstrate the significant potential of this monitor, which will facilitate the evaluation of interventions (improved fuels, stoves, and ventilation) on indoor air pollution levels and research on the impacts of indoor particle levels on health in. developing countries.
引用
收藏
页码:789 / 799
页数:11
相关论文
共 10 条
[1]  
BUKOWSKI RW, 1978, 973 DEP COMM NAT BUR
[2]   Development and application of protocols for the determination of response of real-time particle monitors to common indoor aerosols [J].
Jenkins, RA ;
Ilgner, RH ;
Tomkins, BA ;
Peters, DW .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2004, 54 (02) :229-241
[3]   Combined optical and ionization measurement techniques for inexpensive characterization of micrometer and submicrometer aerosols [J].
Litton, CD ;
Smith, KR ;
Edwards, R ;
Allen, T .
AEROSOL SCIENCE AND TECHNOLOGY, 2004, 38 (11) :1054-1062
[4]   Studies of the measurement of respirable coal dusts and diesel particulate matter [J].
Litton, CD .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2002, 13 (03) :365-374
[5]  
LITTON CD, 1977, FIRE TECHNOL, V13, P266
[6]  
MILLER JC, 1986, STAT ANAL CHEM, P96
[7]  
SINTON JE, 2004, ENERGY SUSTAIN DEV, V8, P74
[8]   Indoor air pollution in developing countries: recommendations for research [J].
Smith, KR .
INDOOR AIR, 2002, 12 (03) :198-207
[9]   The burden of disease from indoor air pollution in developing countries: comparison of estimates [J].
Smith, KR ;
Mehta, S .
INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2003, 206 (4-5) :279-289
[10]  
Weinert D.W., 2003, P 7 INT S, P209