Numerical simulation of pulsatile non-Newtonian flow in the carotid artery bifurcation

被引:42
作者
Fan, Yubo [1 ]
Jiang, Wentao [2 ]
Zou, Yuanwen [2 ]
Li, Jinchuan [2 ]
Chen, Junkai [2 ]
Deng, Xiaoyan [1 ]
机构
[1] Beihang Univ, Sch Biol Sci & Med Engn, Beijing 100191, Peoples R China
[2] Sichuan Univ, Biomech Engn Lab, Chengdu 610065, Peoples R China
基金
中国国家自然科学基金;
关键词
Casson equation; Hybrid fluid; Newtonian fluid; Carotid artery bifurcation; SLIGHTLY CURVED TUBE; CASSON FLUID; STEADY FLOW; MODEL;
D O I
10.1007/s10409-009-0227-9
中图分类号
TH [机械、仪表工业];
学科分类号
120111 [工业工程];
摘要
Both clinical and post mortem studies indicate that, in humans, the carotid sinus of the carotid artery bifurcation is one of the favored sites for the genesis and development of atherosclerotic lesions. Hemodynamic factors have been suggested to be important in atherogenesis. To understand the correlation between atherogenesis and fluid dynamics in the carotid sinus, the blood flow in artery was simulated numerically. In those studies, the property of blood was treated as an incompressible, Newtonian fluid. In fact, however, the blood is a complicated non-Newtonian fluid with shear thinning and viscoelastic properties, especially when the shear rate is low. A variety of non-Newtonian models have been applied in the numerical studies. Among them, the Casson equation was widely used. However, the Casson equation agrees well only when the shear rate is less than 10 s(-1). The flow field of the carotid bifurcation usually covers a wide range of shear rate. We therefore believe that it may not be sufficient to describe the property of blood only using the Casson equation in the whole flow field of the carotid bifurcation. In the present study, three different blood constitutive models, namely, the Newtonian, the Casson and the hybrid fluid constitutive models were used in the flow simulation of the human carotid bifurcation. The results were compared among the three models. The results showed that the Newtonian model and the hybrid model had very similar distributions of the axial velocity, secondary flow and wall shear stress, but the Casson model resulted in significant differences in these distributions from the other two models. This study suggests that it is not appropriate to only use the Casson equation to simulate the whole flow field of the carotid bifurcation, and on the other hand, Newtonian fluid is a good approximation to blood for flow simulations in the carotid artery bifurcation.
引用
收藏
页码:249 / 255
页数:7
相关论文
共 16 条
[1]
BARBARA MJ, 2006, J BIOMECH, V39, P1116
[2]
FLOW OF A CASSON FLUID IN A SLIGHTLY CURVED TUBE [J].
BATRA, RL ;
JENA, B .
INTERNATIONAL JOURNAL OF ENGINEERING SCIENCE, 1991, 29 (10) :1245-1258
[3]
STEADY FLOW IN A MODEL OF THE HUMAN CAROTID BIFURCATION .2. LASER-DOPPLER ANEMOMETER MEASUREMENTS [J].
BHARADVAJ, BK ;
MABON, RF ;
GIDDENS, DP .
JOURNAL OF BIOMECHANICS, 1982, 15 (05) :363-378
[4]
STEADY FLOW IN A MODEL OF THE HUMAN CAROTID BIFURCATION .1. FLOW VISUALIZATION [J].
BHARADVAJ, BK ;
MABON, RF ;
GIDDENS, DP .
JOURNAL OF BIOMECHANICS, 1982, 15 (05) :349-362
[5]
Numerical investigation of the non-Newtonian pulsatile blood flow in a bifurcation model with a non-planar branch [J].
Chen, J ;
Lu, XY .
JOURNAL OF BIOMECHANICS, 2006, 39 (05) :818-832
[6]
SECONDARY FLOW OF A CASSON FLUID IN A SLIGHTLY CURVED TUBE [J].
DAS, B ;
BATRA, RL .
INTERNATIONAL JOURNAL OF NON-LINEAR MECHANICS, 1993, 28 (05) :567-577
[7]
HERNAN AG, 2005, APPL MATH COMPUT, V170, P909
[8]
Hemodynamics analyses of arterial expansions with implications to thrombosis and restenosis [J].
Hyun, S ;
Kleinstreuer, C ;
Archie, JP .
MEDICAL ENGINEERING & PHYSICS, 2000, 22 (01) :13-27
[9]
Numerical simulation of the flow in the carotid bifurcation [J].
Jou, LD ;
Berger, SA .
THEORETICAL AND COMPUTATIONAL FLUID DYNAMICS, 1998, 10 (1-4) :239-248
[10]
PULSATILE FLOW IN A MODEL CAROTID BIFURCATION [J].
KU, DN ;
GIDDENS, DP .
ARTERIOSCLEROSIS, 1983, 3 (01) :31-39