Dural substitute with polyglycolic acid mesh and fibrin glue for dural repair: technical note and preliminary results

被引:49
作者
Shimada, Yoichi
Hongo, Michio
Miyakoshi, Naohisa
Sugawara, Taku
Kasukawa, Yuji
Ando, Shigeru
Ishikawa, Yoshinori
Itoi, Eiji
机构
[1] Akita Univ, Sch Med, Div Orthopaed Surg, Dept Neuro & Locomotor Sci, Akita 0108543, Japan
[2] Akita Univ, Sch Med, Div Neurosurg, Dept Neuro & Locomotor Sci, Akita 0108543, Japan
关键词
D O I
10.1007/s00776-006-1044-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. An ideal dural substitute that enables watertight closure, has sufficient strength, and can be absorbed without remnant materials that induce inflammation, adhesion, and infection is not available. The purpose of this study was to evaluate the efficacy of a bioabsorbable polyglycolic acid (PGA) mesh and fibrin glue as a substitute for dural repair. Methods. Altogether, 10 patients with noted dural tears during extradural spinal surgery and 20 patients who underwent durotomy for intradural spinal surgery were included in this study. In a series of 20 consecutive cases, dural closure was performed by suture and fibrin glue. In the subsequent 10 consecutive patients, dural closure was performed by suture and fibrin glue with the use of absorbable PGA mesh. The medical records and magnetic resonance imaging (MRI) of the surgical site were retrospectively reviewed to evaluate the presence of a cerebrospinal fluid (CSF) fistula or leakage after the surgery. Results. A CSF fistula occurred in five patients who underwent dural repair with fibrin glue alone, and postoperative MRI showed CSF leakage in two patients with incidental dural tears after laminectomy for ossification of ligamentum flavum. No CSF fistula was present in patients who underwent dural repair using PGA mesh and fibrin glue, and no adverse effects or complications were encountered postoperatively. Follow-up MRI revealed no evidence of CSF leakage around the reconstructed dura mater. Conclusions. The use of PGA mesh and fibrin glue for the repair of dura mater is a useful method of preventing CSF leakage in spinal surgery.
引用
收藏
页码:454 / 458
页数:5
相关论文
共 19 条
[1]   Cerebrospinal fluid leaks following spinal surgery: use of fat grafts for prevention and repair - Technical note [J].
Black, P .
JOURNAL OF NEUROSURGERY, 2002, 96 (02) :250-252
[2]  
Bosacco SJ, 2001, CLIN ORTHOP RELAT R, P238
[3]  
Couture Daniel, 2003, Neurosurg Focus, V15, pE6
[4]   TREATMENT OF DURAL TEARS ASSOCIATED WITH SPINAL SURGERY [J].
EISMONT, FJ ;
WIESEL, SW ;
ROTHMAN, RH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (07) :1132-1136
[5]   NORMAL FLOW PATTERNS OF INTRACRANIAL AND SPINAL CEREBROSPINAL-FLUID DEFINED WITH PHASE-CONTRAST CINE MR IMAGING [J].
ENZMANN, DR ;
PELC, NJ .
RADIOLOGY, 1991, 178 (02) :467-474
[6]   EXPERIMENTAL EVALUATION OF BILAYERED HUMAN COLLAGEN AS A DURAL SUBSTITUTE [J].
LAQUERRIERE, A ;
YUN, J ;
TIOLLIER, J ;
HEMET, J ;
TADIE, M .
JOURNAL OF NEUROSURGERY, 1993, 78 (03) :487-491
[7]   COLLAGEN VICRYL - A NEW DURAL PROSTHESIS [J].
MEDDINGS, N ;
SCOTT, R ;
BULLOCK, R ;
FRENCH, DA ;
HIDE, TA ;
GORHAM, SD .
ACTA NEUROCHIRURGICA, 1992, 117 (1-2) :53-58
[8]   Postoperative infection after duraplasty with expanded polytetrafluoroethylene sheet [J].
Nakagawa, S ;
Hayashi, T ;
Anegawa, S ;
Nakashima, S ;
Shimokawa, S ;
Furukawa, Y .
NEUROLOGIA MEDICO-CHIRURGICA, 2003, 43 (03) :120-124
[9]   NEW BIOABSORBABLE PLEDGETS AND NONWOVEN FABRICS MADE FROM POLYGLYCOLIDE (PGA) FOR PULMONARY SURGERY - CLINICAL-EXPERIENCE [J].
NAKAMURA, T ;
SHIMIZU, Y ;
WATANABE, S ;
HITOMI, S ;
KITANO, M ;
TAMADA, J ;
MATSUNOBE, S .
THORACIC AND CARDIOVASCULAR SURGEON, 1990, 38 (02) :81-85
[10]   VICRYL (POLYGLACTIN-910) MESH AS A DURAL SUBSTITUTE IN THE PRESENCE OF PIA ARACHNOID INJURY [J].
NUSSBAUM, CE ;
MAURER, PK ;
MCDONALD, JV .
JOURNAL OF NEUROSURGERY, 1989, 71 (01) :124-127