摘要
Background: Many gastroenterologists believe that disposable forceps are more expensive than reusable forceps. It has been shown, however, that cross contamination and spread of infection are possible with reusable forceps. We conducted a prospective, randomized study to evaluate the performance, safety and cost of reusable versus disposable biopsy forceps. Methods: Endoscopists were randomly assigned reusable or disposable biopsy forceps during upper and lower endoscopy Forceps were evaluated for ease of passage through the endoscope, ease of opening and closing, adequacy of sample, and overall evaluation following the endoscopy using an ordinal scale. The cost per biopsy session was calculated using the following formula: (Acquisition cost + Reprocessing costs)/Number of biopsy sessions. Results: Disposable forceps received a predominantly excellent rating versus a predominantly good rating for reusable forceps. Disposable forceps were also found to be more cast-effective than reusable forceps with an average savings of $5.94 per biopsy session. Examination of reusable forceps revealed residual patient debris despite "adequate" cleansing. Conclusions: Disposable forceps outperformed reusable forceps and were found to be more cost-effective. Residual patient debris on reusable forceps may pose a risk of cross contamination and the spread of infection.
引用
收藏
页码:257 / 261
页数:5
相关论文
共 18 条
[1]  
*ASGE, 1988, GASTROINTEST ENDOS S, V34, pS37
[2]   VIRAL HEPATITIS-B INFECTION RISK IN FLEXIBLE FIBEROPTIC ENDOSCOPY [J].
BOND, WW ;
MONCADA, RE .
GASTROINTESTINAL ENDOSCOPY, 1978, 24 (05) :225-230
[3]  
BOND WW, 1987, JAMA-J AM MED ASSOC, V257, P843
[4]  
BOND WW, 1991, DISINFECTION STERILI, P1097
[5]  
BOND WW, 1987, ENDOSC REV JAN, P55
[6]   Patient-to-patient transmission of hepatitis C virus during colonoscopy [J].
Bronowicki, JP ;
Venard, V ;
Botte, C ;
Monhoven, N ;
Gastin, I ;
Chone, L ;
Hudziak, H ;
Rhin, B ;
Delanoe, C ;
LeFaou, A ;
Bigard, MA ;
Gaucher, P .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 337 (04) :237-240
[7]   SALMONELLA NEWPORT INFECTIONS TRANSMITTED BY FIBEROPTIC COLONOSCOPY [J].
DWYER, DM ;
KLEIN, EG ;
ISTRE, GR ;
ROBINSON, MG ;
NEUMANN, DA ;
MCCOY, GA .
GASTROINTESTINAL ENDOSCOPY, 1987, 33 (02) :84-87
[8]  
Gorse G J, 1991, Gastroenterol Nurs, V14, P72, DOI 10.1097/00001610-199110000-00003
[9]   IDENTIFICATION OF HELICOBACTER-PYLORI DNA IN THE MOUTHS AND STOMACHS OF PATIENTS WITH GASTRITIS USING PCR [J].
MAPSTONE, NP ;
LYNCH, DAF ;
LEWIS, FA ;
AXON, ATR ;
TOMPKINS, DS ;
DIXON, MF ;
QUIRKE, P .
JOURNAL OF CLINICAL PATHOLOGY, 1993, 46 (06) :540-543
[10]   APIC GUIDELINE FOR INFECTION PREVENTION AND CONTROL IN FLEXIBLE ENDOSCOPY [J].
MARTIN, MA ;
REICHELDERFER, M .
AMERICAN JOURNAL OF INFECTION CONTROL, 1994, 22 (01) :19-38