A comparison of the reproducibility and the sensitivity to change of visual analogue scales, Borg scales, and Likert scales in normal subjects during submaximal exercise

被引:380
作者
Grant, S
Aitchison, T
Henderson, E
Christie, J
Zare, S
McMurray, J
Dargie, H
机构
[1] Univ Glasgow, Inst Biomed & Life Sci, Ctr Exercise Sci & Med, Glasgow G12 8LT, Lanark, Scotland
[2] Univ Glasgow, Dept Stat, Glasgow, Lanark, Scotland
[3] Univ Glasgow, Western Infirm, Dept Cardiol, Glasgow G11 6NT, Lanark, Scotland
关键词
breathlessness; exercise testing; general fatigue; reproducibility; sensitivity; subjective scales;
D O I
10.1378/chest.116.5.1208
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To assess which subjective scale, the visual analogue scale (VAS), the Borg CR10 (Borg) scale, or the Likert scale (LS), if any, is decidedly more reproducible and sensitive to change in the assessment of symptoms. Design: Prospective clinical study. Setting: Exercise laboratory. Participants: Twenty-three physically active male subjects (mean +/- SD age of 30 +/- 4 years old) were recruited. Intervention: Each subject attended the exercise laboratory on four occasions at intervals of 1 week. Three subjective scales were used: (1) the VAS (continuous scale); (2) the Borg scale (12 fixed points); and (3) the Likert scale (LS; 5 fixed points). Four identical submaximal tests were given (2 min at 60% maximum oxygen uptake [(V)over dot O(2)max] and 6 min at 70% (V)over dot O(2)max). Two tests were undertaken to assess the reproducibility of scores that were obtained with each subjective scale. Two other tests were undertaken to assess the sensitivity of each scale to a change in symptom perception: a double-blind treatment with propranolol, 80 mg, (ie, active therapy; to increase the sensation of breathlessness and general fatigue during exercise) or matching placebo. The subjective scale scores were measured at 1 min 30 s, 5 min 30 s, and 7 min 15 s of exercise. Reproducibility was defined as the proportion of total variance tie, between-subject plus within-subject variance) explained by the between-subject variance given as a percentage. Sensitvity was defined as the effect of the active drug therapy over the variation within subjects. Results: Overall, the VAS performed best in terms of reproducibility for breathlessness and general fatigue, with reproducibility coefficients as high as 78%. For sensitivity the VAS nas best for breathlessness (ratio, 2.7) and the Borg scale was most sensitive for general fatigue (ratio, 3.0). The relationships between the respective psychological and physiologic variables were reasonably stable throughout the testing procedure, with overall typical correlations of 0.73 to 0.82. Conclusion: This study suggests that subjective scales can reproducibility measure symptoms during steady-state exercise and can detect the effect of a drug intervention. The VAS and Borg scales appear to be the best subjective scales for this purpose.
引用
收藏
页码:1208 / 1217
页数:10
相关论文
共 32 条
[1]   PSYCHOPHYSICAL BASES OF PERCEIVED EXERTION [J].
BORG, GAV .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1982, 14 (05) :377-381
[2]  
*BRIT ASS SPORTS S, 1988, POS STAT PHYS ASS EL
[3]   OPTIMIZING THE EXERCISE PROTOCOL FOR CARDIOPULMONARY ASSESSMENT [J].
BUCHFUHRER, MJ ;
HANSEN, JE ;
ROBINSON, TE ;
SUE, DY ;
WASSERMAN, K ;
WHIPP, BJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (05) :1558-1564
[4]  
BUSSE MW, 1991, J PHYSL, V60, P217
[5]   A CRITICAL-REVIEW OF THE LITERATURE ON RATINGS SCALES FOR PERCEIVED EXERTION [J].
CARTON, RL ;
RHODES, EC .
SPORTS MEDICINE, 1985, 2 (03) :198-222
[6]   EFFECT OF HYPEROXIA AND HYPOXIA ON EXERCISE-INDUCED BREATHLESSNESS IN NORMAL SUBJECTS [J].
CHRONOS, N ;
ADAMS, L ;
GUZ, A .
CLINICAL SCIENCE, 1988, 74 (05) :531-537
[7]  
COSTILL DL, 1973, MED SCI SPORT EXER, V5, P248
[8]   EFFECTS OF ATROPINE AND PRACTOLOL ON THE PERCEPTION OF EXERTION DURING TREADMILL EXERCISE [J].
DAVIES, CTM ;
SARGEANT, AJ .
ERGONOMICS, 1979, 22 (10) :1141-1146
[9]   BREATHLESSNESS DURING EXERCISE WITH AND WITHOUT RESISTIVE LOADING [J].
ELMANSHAWI, A ;
KILLIAN, KJ ;
SUMMERS, E ;
JONES, NL .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 61 (03) :896-905
[10]   A COMPARISON OF LIKERT AND VISUAL ANALOG SCALES FOR MEASURING CHANGE IN FUNCTION [J].
GUYATT, GH ;
TOWNSEND, M ;
BERMAN, LB ;
KELLER, JL .
JOURNAL OF CHRONIC DISEASES, 1987, 40 (12) :1129-1133