Meniscal tissue regeneration in porous 50/50 copoly(L-lactide/epsilon-caprolactone) implants

被引:90
作者
deGroot, JH
Zijlstra, FM
Kuipers, HW
Pennings, AJ
Klompmaker, J
Veth, RPH
Jansen, HWB
机构
[1] UNIV GRONINGEN, DEPT POLYMER CHEM, NL-9747 AG GRONINGEN, NETHERLANDS
[2] UNIV NIJMEGEN HOSP, DEPT ORTHOPAED SURG, NL-6500 HB NIJMEGEN, NETHERLANDS
[3] UNIV GRONINGEN, BIOMAT RES CTR, NL-9712 KZ GRONINGEN, NETHERLANDS
关键词
meniscal repair; porous materials; polyester; degradation;
D O I
10.1016/S0142-9612(96)00169-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Porous materials of a high-molecular-weight 50/50 copolymer of L-lactide and epsilon-caprolactone with different compression moduli were used for meniscal repair. In contrast to the previously used 4,4'-diphenylmethane and 1,6-trans-cyclohexane diisocyanates containing polyurethanes, degradation products of the copolymer are non-toxic. Two series of porous materials with compression moduli of 40 and 100 kPa respectively were implanted in the knees of dogs using a new, less traumatizing suturing technique. A porous aliphatic polyurethane series with compression modulus of 150 kPa was implanted for comparison. Adhesion of the implant to meniscal tissue was found to be essential for healing of the longitudinal lesion. Copolymer implants showed better adhesion, probably due to the higher degradation rate of the copolymer. Fibrocartilage formation was found to be affected by the compression modulus of the implant. Implants with a modulus of 40 kPa did not show ingrowth of fibrocartilage, whereas implants with compression moduli of 100 and 150 kPa yielded 50-70 and 80-100% fibrocartilage respectively. During degradation the copolymer phase separated into a crystalline phase containing mainly L-lactide and an amorphous phase containing mainly epsilon-caprolactone. The copolymer degraded through bulk degradation. (C) 1997 Elsevier Science Limited.
引用
收藏
页码:613 / 622
页数:10
相关论文
共 36 条
[1]  
ARCHER CW, 1990, J CELL SCI, V97, P361
[2]   WINNER OF THE 1982 ODONOGHUE AWARD - THE MICROVASCULATURE OF THE MENISCUS AND ITS RESPONSE TO INJURY - AN EXPERIMENTAL-STUDY IN THE DOG [J].
ARNOCZKY, SP ;
WARREN, RF .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1983, 11 (03) :131-141
[3]   MENISCAL REPAIR USING AN EXOGENOUS FIBRIN CLOT - AN EXPERIMENTAL-STUDY IN DOGS [J].
ARNOCZKY, SP ;
WARREN, RF ;
SPIVAK, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (08) :1209-1216
[4]   LOW-DENSITY, MICROCELLULAR POLYSTYRENE FOAMS [J].
AUBERT, JH ;
CLOUGH, RL .
POLYMER, 1985, 26 (13) :2047-2054
[5]  
BENJAMIN M, 1990, J ANAT, V171, P1
[6]   FOREIGN-BODY REACTIONS TO RESORBABLE POLY(L-LACTIDE) BONE PLATES AND SCREWS USED FOR THE FIXATION OF UNSTABLE ZYGOMATIC FRACTURES [J].
BERGSMA, EJ ;
ROZEMA, FR ;
BOS, RRM ;
DEBRUIJN, WC .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (06) :666-670
[7]  
CAPLAN AI, 1984, SCI AM, V4, P82
[8]   MENISCAL REPAIR BY SYNOVIAL FLAP TRANSFER - HEALING OF THE AVASCULAR ZONE IN RABBITS [J].
CISA, J ;
BASORA, J ;
MADARNAS, P ;
GHIBELY, A ;
NAVARROQUILIS, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1995, 66 (01) :38-40
[9]  
Day B, 1985, Arthroscopy, V1, P58, DOI 10.1016/S0749-8063(85)80080-3
[10]  
DEDUNNEN WFA, 1993, MICROSURG, V14, P508