Blue Mode Imaging may Improve the Detection and Visualization of Small-Bowel Lesions: A Capsule Endoscopy Study

被引:12
作者
Abdelaal, Usama M. [1 ,2 ]
Morita, Eijiro [1 ]
Nouda, Sadaharu [1 ]
Kuramoto, Takanori [1 ]
Miyaji, Katsuhiko [1 ]
Fukui, Hideo [1 ]
Tsuda, Yasuhiro [1 ]
Fukuda, Akira [1 ]
Murano, Mitsuyuki [1 ]
Tokioka, Satoshi [1 ]
Umegaki, Eiji [1 ]
Arfa, Usama A. [2 ]
Higuchi, Kazuhide [1 ]
机构
[1] Osaka Med Coll, Dept Internal Med 2, Takatsuki, Osaka 5688686, Japan
[2] Sohag Univ, Dept Internal Med, Sohag, Egypt
关键词
Blue mode; capsule endoscopy; QuickView; SUSPECTED BLOOD INDICATOR; DIAGNOSTIC-YIELD; METAANALYSIS; SOFTWARE; CHROMOENDOSCOPY; MODALITIES; QUICKVIEW; DISEASES; TIME;
D O I
10.4103/1319-3767.170954
中图分类号
R57 [消化系及腹部疾病];
学科分类号
100201 [内科学];
摘要
Background/Aims: Diagnostic miss rate and time consumption are the two challenging limitations of small-bowel capsule endoscopy (SBCE). In this study, we aimed to know whether using of the blue mode (BM) combined with QuickView (QV) at a high reviewing speed could influence SBCE interpretation and accuracy. Materials and Methods: Seventy CE procedures were totally reviewed in four different ways; (1) using the conventional white light, (2) using the BM, [on a viewing speed at 10 frames per second (fps)], (3) using white light, and (4) using the BM (on a viewing speed at 20 fps). In study A, the results of (1) were compared with those of (2), and in study B, the results of (3) and (4) were separately compared with those of (1). Results: In study A, the total number of the vascular (P < 0.001) and the inflammatory lesions (P = 0.005) detected by BM was significantly higher than that detected by the white light. No lesion was found using the white light that was not detected by the BM. Moreover, the BM highly improved the image quality of all the vascular lesions and the erythematous ones from the nonvascular lesions. In study B, the total number of only the vascular lesions, detected by the BM on a rapid speed of viewing at 20 fps was significantly higher than that detected by the white light (P = 0.035). However, the true miss rate for the BM was 4%. Conclusion: BM imaging is a new method that improved the detection and visualization of the vascular and erythematous nonvascular lesions of SB as compared with the conventional white light imaging. Using of the BM at a slow viewing speed, markedly reduced the diagnostic miss rate of CE.
引用
收藏
页码:418 / 422
页数:5
相关论文
共 21 条
[1]
ABDELAAL UM, 2010, GASTROINTEST ENDOSC, V71, pAB367
[2]
Virtual chromoendoscopy in small bowel capsule endoscopy: New light or a cast of shadow? [J].
Cotter, Jose ;
Magalhaes, Joana ;
de Castro, Francisca Dias ;
Barbosa, Mara ;
Carvalho, Pedro Boal ;
Leite, Silvia ;
Moreira, Maria Joao ;
Rosa, Bruno .
WORLD JOURNAL OF GASTROINTESTINAL ENDOSCOPY, 2014, 6 (08) :359-365
[3]
Capsule endoscopy in 2005: Facts and perspectives [J].
Delvaux, M ;
Gay, G .
BEST PRACTICE & RESEARCH CLINICAL GASTROENTEROLOGY, 2006, 20 (01) :23-39
[4]
Evaluation of Quickview® System and Suspected Blood Indicator® Test from of Given M2A Plus® Capsule Endoscopy Software in the Clinical Setting [J].
Diaz, Angel Ponferrada ;
Viso, Luis Menchen ;
Asanza, Cecilia Gonzalez ;
Arregui, Enrique Cos ;
Fernandez-Pacheco, Pedro Menchen .
GASTROINTESTINAL ENDOSCOPY, 2006, 63 (05) :AB227-AB227
[5]
Capsule Endoscopy Has a Significantly Higher Diagnostic Yield in Patients With Suspected and Established Small-Bowel Crohn's Disease: A Meta-Analysis [J].
Dionisio, Paula M. ;
Gurudu, Suryakanth R. ;
Leighton, Jonathan A. ;
Leontiadis, Grigoris I. ;
Fleischer, David E. ;
Hara, Amy K. ;
Heigh, Russell I. ;
Shiff, Arthur D. ;
Sharma, Virender K. .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2010, 105 (06) :1240-1248
[6]
Duque G, 2012, REV ESP ENFERM DIG, V104, P231, DOI 10.4321/s1130-01082012000500002
[7]
Present status and strategy of NSAIDs-induced small bowel injury [J].
Higuchi, Kazuhide ;
Umegaki, Eiji ;
Watanabe, Toshio ;
Yoda, Yukiko ;
Morita, Eijiro ;
Murano, Mitsuyuki ;
Tokioka, Satoshi ;
Arakawa, Tetsuo .
JOURNAL OF GASTROENTEROLOGY, 2009, 44 (09) :879-888
[8]
Evaluations of capsule endoscopy software in reducing the reading time and the rate of false negatives by inexperienced endoscopists [J].
Hosoe, Naoki ;
Rey, Jean-Francois ;
Imaeda, Hiroyuki ;
Bessho, Rieko ;
Ichikawa, Riko ;
Ida, Yosuke ;
Naganuma, Makoto ;
Kanai, Takanori ;
Hibi, Toshifumi ;
Ogata, Haruhiko .
CLINICS AND RESEARCH IN HEPATOLOGY AND GASTROENTEROLOGY, 2012, 36 (01) :66-71
[9]
QuickView in small-bowel capsule endoscopy is useful in certain clinical settings, but QuickView with Blue Mode is of no additional benefit [J].
Koulaouzidis, Anastasios ;
Smirnidis, Alexandros ;
Douglas, Sarah ;
Plevris, John N. .
EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2012, 24 (09) :1099-1104
[10]
Chromoendoscopy in small bowel capsule endoscopy: Blue mode or Fuji Intelligent Colour Enhancement? [J].
Krystallis, Christoforos ;
Koulaouzidis, Anastasios ;
Douglas, Sarah ;
Plevris, John N. .
DIGESTIVE AND LIVER DISEASE, 2011, 43 (12) :953-957