Wideband harmonic imaging: A novel contrast ultrasound imaging technique

被引:29
作者
Bauer, A [1 ]
Hauff, P
Lazenby, J
von Behren, P
Zomack, M
Reinhardt, M
Schlief, R
机构
[1] Schering AG, Clin Dev Diagnost, D-13342 Berlin, Germany
[2] Siemens Med Syst Inc, Issaquah, WA USA
关键词
D O I
10.1007/PL00014075
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A novel ultrasonic imaging method, wideband harmonic imaging, for nonlinear imaging of microbubble contrast agents is evaluated. In wideband harmonic mode, two pulses of alternate phase are send out. The image is then processed from the sum of both pulses, resulting in an image of nonlinear scatterers such as microbubbles. A prototype ultrasound system, Siemens Elegra, was evaluated with in vitro investigations and animal trials, using conventional, harmonic and wideband harmonic settings with the galactose based ultrasound contrast agent Levovist. Wideband harmonic imaging offers superior sensitivity for ultrasound contrast agents compared to conventional imaging and harmonic imaging. At low transmit power settings (MI 0.1-0.5) the nonlinear response is already sufficient to generate a image of the blood pool distribution of Levovist in the rabbit kidney including the microvasculature, with clear delineation of vessels and perfused parenchyma. At high transmit amplitudes, nonlinear tissue response reduced the apparent image contrast between contrast agent and tissue. The results suggest that wideband harmonic imaging is currently the most sensitive contrast imaging technique, maintaining highest spatial resolution. This may add to image quality and offer new clinical potential for the use of ultrasound contrast agents such as Levovist.
引用
收藏
页码:S364 / S367
页数:4
相关论文
共 11 条
[1]  
Bauer A, 1998, ECHOENHANCERS AND TRANSCRANIAL COLOR DUPLEX SONOGRAPHY, P204
[2]  
BAUER A, 1997, EUR J ULTRASOUND, V6, P34
[3]   Stimulated acoustic emission in liver parenchyma with Levovist [J].
Blomley, M ;
Albrecht, T ;
Cosgrove, D ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, R .
LANCET, 1998, 351 (9102) :568-568
[4]   Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: Early experience [J].
Blomley, MJK ;
Albrecht, T ;
Cosgrove, DO ;
Patel, N ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, RJ ;
Bauer, A ;
Schlief, R .
RADIOLOGY, 1999, 210 (02) :409-416
[5]   Sound radiation of 3-MHz driven gas bubbles [J].
Grossmann, S ;
Hilgenfeldt, S ;
Lohse, D ;
Zomack, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (02) :1223-1230
[6]   Response of bubbles to diagnostic ultrasound: a unifying theoretical approach [J].
Hilgenfeldt, S ;
Lohse, D ;
Zomack, M .
EUROPEAN PHYSICAL JOURNAL B, 1998, 4 (02) :247-255
[7]   Transmit aperture processing for nonlinear contrast agent imaging [J].
Krishnan, S ;
ODonnell, M .
ULTRASONIC IMAGING, 1996, 18 (02) :77-105
[8]   NONLINEAR PROPAGATION IN DOPPLER ULTRASOUND [J].
LI, S ;
MCDICKEN, WN ;
HOSKINS, PR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (05) :359-364
[9]  
PORTER T, 1996, 1 EUR S ULTR CONTR I
[10]  
Rayleigh, 1917, PHILOS MAG, V34, P94, DOI [10.1080/14786440808635681, DOI 10.1080/14786440808635681]