Comparative evaluation of the performance of the Abbott real-time human immunodeficiency virus type I (HIV-1) assay for measurement of HIV-1 plasma viral load following automated specimen preparation

被引:33
作者
Garcia-Diaz, A.
Clewley, G. S.
Booth, C. L.
Labett, W.
McAllister, N.
Geretti, A. M.
机构
[1] UCL Royal Free Hosp, Dept Virol, London NW3 2PF, England
[2] UCL Royal Free & Univ Coll Med Sch, London NW3 2PF, England
关键词
D O I
10.1128/JCM.44.5.1788-1791.2006
中图分类号
Q93 [微生物学];
学科分类号
071005 [微生物学]; 100705 [微生物与生化药学];
摘要
The performance of the new Abbott real-time human immunodeficiency virus type 1 (HIV-1) assay for HIV-1 RNA load determination in plasma was compared to that of the Abbott LCx HIV-1 RNA quantitative assay following automated RNA isolation by the Abbott m1000 extractor. The measured viral loads of 89 clinical specimens differed by mean 0.19 log(10) copies/ml (95% confidence interval, 0.12 to 0.26 log(10) copies/ml). Although the difference in viral load determinations was positively skewed in favor of the LCx assay, it did not reach statistical significance (P = 0.42). Results were linearly associated (R-2 = 0.94) and strongly correlated (R = 0.96). Good performance was observed with HIV-1 subtypes other than B and circulating recombinant forms, although results obtained with two subtype G specimens and one H specimen showed a more substantial difference.
引用
收藏
页码:1788 / 1791
页数:4
相关论文
共 11 条
[1]
Comparison of LCx with other current viral load assays for detecting and quantifying human immunodeficiency virus type 1 RNA in patients infected with the circulating recombinant form A/G (CRF02) [J].
Amendola, A ;
Bordi, L ;
Angeletti, C ;
Girardi, E ;
Ippolito, G ;
Capobianchi, MR .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (02) :811-815
[2]
ANNETTE A, 1997, AIDS, V11, P859
[3]
Bankowski M. J., 2004, Clinical Microbiology Newsletter, V26, P9, DOI 10.1016/S0196-4399(04)90003-7
[4]
Evaluation of the Abbott LCx quantitative assay for measurement of human immunodeficiency virus RNA in plasma [J].
de Mendoza, C ;
Alcamí, J ;
Sainz, M ;
Folgueira, D ;
Soriano, V .
JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (04) :1518-1521
[5]
HIV-1 subtypes in Spain: a retrospective analysis from 1995 to 2003 [J].
Lospitao, E ;
Alvarez, A ;
Soriano, V ;
Holguin, A .
HIV MEDICINE, 2005, 6 (05) :313-320
[6]
Development of calibrated viral load standards for group M subtypes of human immunodeficiency virus type 1 and performance of an improved AMPLICOR HIV-1 MONITOR test with isolates of diverse subtypes [J].
Michael, NL ;
Herman, SA ;
Kwok, S ;
Dreyer, K ;
Wang, J ;
Christopherson, C ;
Spadoro, JP ;
Young, KKY ;
Polonis, V ;
McCutchan, FE ;
Carr, J ;
Mascola, JR ;
Jagodzinsi, LL ;
Robb, ML .
JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (08) :2557-2563
[7]
Smith T. F., 2004, Clinical Microbiology Newsletter, V26, P145, DOI 10.1016/j.clinmicnews.2004.09.002
[8]
Quantification of HIV-1 group M (subtypes A-G) and group O by the LCx HIV RNA quantitative assay [J].
Swanson, P ;
Harris, BJ ;
Holzmayer, V ;
Devare, SG ;
Schochetman, G ;
Hackett, J .
JOURNAL OF VIROLOGICAL METHODS, 2000, 89 (1-2) :97-108
[9]
Impact of human immunodeficiency virus type 1 (HIV-1) genetic diversity on performance of four commercial viral load assays: LCx HIV RNA quantitative, AMPLICOR HIV-1 MONITOR v1.5, VERSANT HIV-1 RNA 3.0, and NucliSens HIV-1 QT [J].
Swanson, P ;
de Mendoza, C ;
Joshi, Y ;
Golden, A ;
Hodinka, RL ;
Soriano, V ;
Devare, SG ;
Hackett, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (08) :3860-3868
[10]
Efficiencies of four versions of the AMPLICOR HIV-1 MONITOR test for quantification of different subtypes of human immunodeficiency virus type 1 [J].
Triques, K ;
Coste, J ;
Perret, JL ;
Segarra, C ;
Mpoudi, E ;
Reynes, J ;
Delaporte, E ;
Butcher, A ;
Dreyer, K ;
Herman, S ;
Spadoro, J ;
Peeters, M .
JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (01) :110-116