Ultrasound elastography is a reproducible and feasible tool for the evaluation of the patellar tendon in healthy subjects

被引:61
作者
Porta, F. [1 ]
Damjanov, N. [2 ]
Galluccio, F. [1 ]
Iagnocco, A. [3 ]
Matucci-Cerinic, M. [1 ]
机构
[1] Univ Florence, Dept Sperimental & Clin Med, Div Rheumatol AOUC, Florence, Italy
[2] Univ Belgrade, Sch Med, Inst Rheumatol, Belgrade, Serbia
[3] Univ Roma La Sapienza, Dipartimento Med Interna & Special Med Reumatol, I-00185 Rome, Italy
关键词
feasibility; healthy subjects; patellar tendon; reproducibility; ultrasound elastography; REAL-TIME SONOELASTOGRAPHY; PATTERN DESCRIPTION; ACHILLES TENDONS; RHEUMATOLOGY; VOLUNTEERS;
D O I
10.1111/1756-185X.12241
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Objective: To evaluate the feasibility and reproducibility of ultrasound elastography (UE) in the assessment of healthy patellar tendon and to describe its UE pattern. Methods: Twenty-two patellar tendons of 11 out of 16 healthy subjects who met the inclusion criteria were evaluated three times by ultrasound (US) and UE at their proximal, middle and distal portions, by two separate sonographers with different experiences in UE. Results: In all tendon portions the color map analysis showed a predominance of green (highly elastic), with good values of intra-observer (Operator 1: P-values = 0.790, 0.864, 0.865; Operator 2: P = 0.642, 0.882, 0.613 for proximal, middle and distal portions, respectively) and inter-observer (P = 0.657) agreement. For both operators the intra-observer analysis of the elasticity ratio (ER) between the tendon and the subcutis showed high agreement values (P < 0.001 for both operators). The inter-observer analysis showed also high agreement values (P < 0.001 at proximal, P = 0.001 at middle, P = 0.005 at distal portions). The overall analysis of the ER of the tendon portions showed values of (mean +/- SD): 1.47 +/- 0.64, 4.38 +/- 1.36, 3.32 +/- 1.20 for proximal, middle and distal portions, respectively. The mean time to perform the UE evaluation for the inexperienced operator was 5 min at the beginning of the study but decreased to 2 min after a few examinations were done. The mean time for the expert was 2 min for the entire study. Conclusions: UE is a feasible and reproducible tool for the evaluation of the healthy patellar tendon and further data are needed to define its role in the assessment of tendon pathology.
引用
收藏
页码:760 / 764
页数:5
相关论文
共 12 条
[1]
Real-Time Sonoelastography: Findings in Patients with Symptomatic Achilles Tendons and Comparison to Healthy Volunteers [J].
De Zordo, T. ;
Chhem, R. ;
Smekal, V. ;
Feuchtner, G. ;
Reindl, M. ;
Fink, C. ;
Faschingbauer, R. ;
Jaschke, W. ;
Klauser, A. S. .
ULTRASCHALL IN DER MEDIZIN, 2010, 31 (04) :394-400
[2]
Real-Time Sonoelastography Findings in Healthy Achilles Tendons [J].
De Zordo, Tobias ;
Fink, Christian ;
Feuchtner, Gudrun M. ;
Smekal, Vinzenz ;
Reindl, Markus ;
Klauser, Andrea Sabine .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (02) :W134-W138
[3]
Real-Time Sonoelastography of Lateral Epicondylitis: Comparison of Findings Between Patients and Healthy Volunteers [J].
De Zordo, Tobias ;
Lill, Stephanie R. ;
Fink, Christian ;
Feuchtner, Gudrun M. ;
Jaschke, Werner ;
Bellmann-Weiler, Rosa ;
Klauser, Andrea S. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (01) :180-185
[4]
Real-time ultrasound elastography of the normal Achilles tendon: reproducibility and pattern description [J].
Drakonaki, E. E. ;
Allen, G. M. ;
Wilson, D. J. .
CLINICAL RADIOLOGY, 2009, 64 (12) :1196-1202
[5]
FORNAGE BD, 1988, RADIOL CLIN N AM, V26, P87
[6]
Ultrasound Elastography Assessment of Skin Involvement in Systemic Sclerosis: Lights and Shadows [J].
Iagnocco, Annamaria ;
Kaloudi, Olga ;
Perella, Chiara ;
Bandinelli, Francesca ;
Riccieri, Valeria ;
Vasile, Massimiliano ;
Porta, Francesco ;
Valesini, Guido ;
Matucci-Cerinic, Marco .
JOURNAL OF RHEUMATOLOGY, 2010, 37 (08) :1688-1691
[7]
Musculoskeletal ultrasound - a state of the art review in rheumatology. Part 1: Current controversies and issues in the development of musculoskeletal ultrasound in rheumatology [J].
Kane, D ;
Balint, PV ;
Sturrock, R ;
Grassi, W .
RHEUMATOLOGY, 2004, 43 (07) :823-828
[8]
Ultrasound of tendons and nerves [J].
Martinoli, C ;
Bianchi, S ;
Dahmane, M ;
Pugliese, F ;
Bianchi-Zamorani, MP ;
Valle, M .
EUROPEAN RADIOLOGY, 2002, 12 (01) :44-55
[9]
Elastography: ultrasonic estimation and imaging of the elastic properties of tissues [J].
Ophir, J ;
Alam, SK ;
Garra, B ;
Kallel, F ;
Konofagou, E ;
Krouskop, T ;
Varghese, T .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H3) :203-233
[10]
Sonography of Common Tendon Injuries [J].
Robinson, Philip .