Clinical value of attenuation correction in stress-only Tc-99m sestamibi SPECT imaging

被引:107
作者
Heller, GV
Bateman, TM
Johnson, LL
Cullom, SJ
Case, JA
Galt, JR
Garcia, EV
Haddock, K
Moutray, KL
Poston, C
Botvinick, EH
Fish, MB
Follansbee, WP
Hayes, S
Iskandrian, AE
Mahmarian, JJ
Vandecker, W
机构
[1] Hartford Hosp, Nucl Cardiol Lab, Ishikari, Hokkaido 06102, Japan
[2] Med Coll Penn & Hahnemann Univ, Philadelphia, PA USA
[3] Baylor Coll, Med Ctr, Houston, TX USA
[4] Univ Alabama, Birmingham, AL USA
[5] Cedars Sinai Med Ctr, Los Angeles, CA 90048 USA
[6] Univ Pittsburgh, Pittsburgh, PA USA
[7] Sacred Heart Med Ctr, Spokane, WA USA
[8] Univ Calif San Francisco, Med Ctr, San Francisco, CA 94143 USA
[9] St Lukes Hosp, Mid Amer Heart Inst, Kansas City, MO 64111 USA
[10] Emory Univ, Atlanta, GA 30322 USA
[11] Rhode Isl Hosp, Providence, RI USA
[12] Cardiovasc Consultants, Kansas City, MO USA
关键词
myocardial perfusion imaging; attenuation correction; single photon emission computed tomography; electrocardiography gating;
D O I
10.1016/j.nuclcard.2004.03.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Attenuation artifact remains a substantial limitation to confident interpretation of images and reduces laboratory efficiency by requiring comparison of stress and rest image sets. Attenuation-corrected stress-only imaging has the potential to ameliorate these limitations. Methods and Results. Ten experienced nuclear cardiologists independently interpreted 90 stress-only electrocardiography (ECG)-gated technetium 99m sestamibi images in a sequential fashion: myocardial perfusion imaging (MPI) alone, MPI plus ECG-gated data, and attenuation-corrected MPI with ECG-gated data. Images were interpreted for diagnostic certainty (normal, probably normal, equivocal, probably abnormal, abnormal, and perceived need for rest imaging). With stress MPI data alone, only 37% of studies were interpreted as definitely normal or abnormal, with a very high perceived need for rest imaging (77%). The addition of gated data did not alter the interpretations. However, attenuation-corrected data significantly increased the number of studies characterized as definitely normal or abnormal (84%, P < .005) and significantly reduced the perceived need for rest imaging (43%, P < .005). These results were confirmed by use of a nonsequential consensus interpretation of three readers. Conclusion. Attenuation correction applied to studies with stress-only Tc-99m ECG-gated single photon emission computed tomography images significantly increases the ability to interpret studies as definitely normal or abnormal and reduces the need for rest imaging. These findings may improve laboratory efficiency and diagnostic accuracy.
引用
收藏
页码:273 / 281
页数:9
相关论文
共 24 条
[1]  
Case JA, 2001, J NUCL MED, V42, p51P
[2]  
Cullom SJ, 2000, J NUCL MED, V41, p134P
[3]  
Cullom SJ, 2000, J NUCL MED, V41, P860
[4]  
DEPUEY E, 1995, J NUCL MED, V36, P952
[5]   Simultaneous transmission emission myocardial perfusion tomography diagnostic accuracy of attenuatian-corrected Tc-99m-sestamibi single-photon emission computed tomography [J].
Ficaro, EP ;
Fessler, JA ;
Shreve, PD ;
Kritzman, JN ;
Rose, PA ;
Corbett, JR .
CIRCULATION, 1996, 93 (03) :463-473
[6]  
Galt JR, 1999, J NUCL MED, V40, p286P
[7]   Low event rate for stress-only perfusion imaging in patients evaluated for chest pain [J].
Gibson, PB ;
Demus, D ;
Noto, R ;
Hudson, W ;
Johnson, LL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (06) :999-1004
[8]  
Hachamovitch R, 1998, CIRCULATION, V97, P535
[9]   Exercise myocardial perfusion SPECT in patients without known coronary artery disease: Incremental prognostic value and use in risk stratification [J].
Hachamovitch, R ;
Berman, DS ;
Kiat, H ;
Cohen, I ;
Cabico, JA ;
Friedman, J ;
Diamond, GA .
CIRCULATION, 1996, 93 (05) :905-914
[10]   Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging [J].
Hendel, RC ;
Berman, DS ;
Cullom, SJ ;
Follansbee, W ;
Heller, GV ;
Kiat, H ;
Groch, MW ;
Mahmarian, JJ .
CIRCULATION, 1999, 99 (21) :2742-2749