Inhibition of endothelium-dependent relaxation by hemoglobin in rabbit aortic strips: Comparison between acellular hemoglobin derivatives and cellular hemoglobins

被引:56
作者
Nakai, K
Ohta, T
Sakuma, I
Akama, K
Kobayashi, Y
Tokuyama, S
Kitabatake, A
Nakazato, Y
Takahashi, TA
Sadayoshi, T
机构
[1] HOKKAIDO RED CROSS CTR,SAPPORO,HOKKAIDO,JAPAN
[2] HOKKAIDO UNIV,GRAD SCH VET MED,PHARMACOL LAB,SAPPORO,HOKKAIDO,JAPAN
[3] HOKKAIDO UNIV,SCH MED,DEPT CARDIOVASC MED,SAPPORO,HOKKAIDO,JAPAN
[4] NOF CO,TSUKUBA RES CTR,TSUKUBA,IBARAKI,JAPAN
关键词
blood substitutes; artificial oxygen carrier; endothelium-dependent vasorelaxation; hemoglobins; vasoconstriction; liposome;
D O I
10.1097/00005344-199607000-00018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Hemoglobin (Hb)-based artificial oxygen carriers are supposed to induce vasoconstriction through the inactivation of endothelium-derived relaxing factor (EDRF). We examined the vasoconstrictive activity of acellular Hb and cellular Hb solutions in rabbit aortic strips. Unmodified Hb, pyridoxalated Hb, bovine unmodified Hb, haptoglobin-Hb complex (Hp-Hb), and polyoxyethylene glycol-conjugated Hb (PEG-Hb) were used as acellular Hbs having different molecular masses. Cellular Hbs included liposome-encapsulated Hb and red blood cells (RBC). In the first experiment, Hb (10 ng/ml to 1 mg/ml) was cumulatively added to the tissues in which steady-state relaxation was evoked by acetylcholine (ACh) after precontraction induced by phenylephrine. Although all Hb solutions induced a dose-dependent reversal of ACh-induced relaxation, the most potent vasoconstrictive effect was noted with acellular Hbs, and their contractile activities were almost the same independent of molecular mass. On the other hand, liposome-Hb and RBC showed reduced potencies in this order. These results indicate the importance of cellularity as the major factor determining Hb-related EDRF inactivation. In another experiment, the tissues were exposed to Hb at 0.01, 0.1, or 1 mg/ml for 30 min and ACh-induced relaxation was recorded after the complete removal of Hb in an organ bath chamber. Exposure to unmodified Hb at >0.1-mg/ml concentrations significantly reduced the ACh-induced relaxation, whereas the relaxation was not affected by PEG-Hb, Hp-Hb, liposome-Hb, or RBC. These results suggest that unmodified Hb might be persistently associated with tissues and thereby inhibit ACh-induced relaxation. From these findings, we propose two attributes of Hb-related inhibition of endothelium-dependent relaxation: Acellular Hbs inhibit EDRF more efficiently in the luminal space than cellular Hbs, and unmodified Hb can also inhibit it adluminally and/or adventitially.
引用
收藏
页码:115 / 123
页数:9
相关论文
共 35 条
  • [1] BLEEKER WK, 1989, J LAB CLIN MED, V113, P151
  • [2] Di Iorio E E, 1981, Methods Enzymol, V76, P57
  • [3] RESUSCITATION WITH DIASPIRIN CROSS-LINKED HEMOGLOBIN IN A PIG MODEL OF HEMORRHAGIC-SHOCK
    DUNLAP, E
    FARRELL, L
    NIGRO, C
    ESTEP, T
    MARCHAND, G
    BURHOP, K
    [J]. ARTIFICIAL CELLS BLOOD SUBSTITUTES AND IMMOBILIZATION BIOTECHNOLOGY, 1995, 23 (01): : 39 - 61
  • [4] HUMAN RED BLOOD-CELLS INHIBIT ENDOTHELIUM-DERIVED RELAXING FACTOR (EDRF) ACTIVITY
    EVANS, HG
    RYLEY, HC
    HALLETT, I
    LEWIS, MJ
    [J]. EUROPEAN JOURNAL OF PHARMACOLOGY, 1989, 163 (2-3) : 361 - 364
  • [5] GOTOH K, 1992, ARTIF ORGANS, V16, P586
  • [6] INCREASED VASCULAR-RESISTANCE WITH HEMOGLOBIN-BASED OXYGEN CARRIERS
    HESS, JR
    MACDONALD, VW
    GOMEZ, CS
    COPPES, V
    [J]. ARTIFICIAL CELLS BLOOD SUBSTITUTES AND IMMOBILIZATION BIOTECHNOLOGY, 1994, 22 (03): : 361 - 372
  • [7] PREPARATION AND EVALUATION OF HEMOGLOBIN POLYETHYLENE-GLYCOL CONJUGATE (PYRIDOXALATED POLYETHYLENE-GLYCOL HEMOGLOBIN) AS AN OXYGEN-CARRYING RESUSCITATION FLUID
    IWASAKI, K
    IWASHITA, Y
    [J]. ARTIFICIAL ORGANS, 1986, 10 (05) : 411 - 416
  • [8] NITRIC-OXIDE MEDIATES THE HYPERTENSIVE RESPONSE TO A MODIFIED HEMOGLOBIN SOLUTION (DCLHB(TM)) IN RATS
    KATSUYAMA, SS
    COLE, DJ
    DRUMMOND, JC
    BRADLEY, K
    [J]. ARTIFICIAL CELLS BLOOD SUBSTITUTES AND IMMOBILIZATION BIOTECHNOLOGY, 1994, 22 (01): : 1 - 7
  • [9] ACUTE CHANGES IN SYSTEMIC BLOOD-PRESSURE AND URINE OUTPUT OF CONSCIOUS RATS FOLLOWING EXCHANGE-TRANSFUSION WITH DIASPIRIN-CROSS-LINKED HEMOGLOBIN SOLUTION
    KEIPERT, PE
    GONZALES, A
    GOMEZ, CL
    MACDONALD, VW
    HESS, JR
    WINSLOW, RM
    [J]. TRANSFUSION, 1993, 33 (09) : 701 - 708
  • [10] KIDA Y, 1991, ARTIF ORGANS, V15, P5