Model based PEM fuel cell state-of-health monitoring via ac impedance measurements

被引:362
作者
Fouquet, N.
Doulet, C.
Nouillant, C.
Dauphin-Tanguy, G.
Ould-Bouamama, B.
机构
[1] PSA Peugeot Citroen, Ctr Tech Velizy, F-78943 Velizy Villacoublay, France
[2] Ecole Cent Lille, CNRS, LAGIS, UMR 8146, F-59651 Villeneuve Dascq, France
关键词
PEM fuel cell; water management; electrochemical impedance spectroscopy; model-based fault detection and isolation;
D O I
10.1016/j.jpowsour.2005.11.035
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The present paper deals with monitoring of flooding and drying out of a proton exchange membrane (PEM) fuel cell using a model-based approach coupled with ac impedance measurements. A study of the impedance response of a 150cm(2) six-cell air/H-2 PEM fuel cell as a function of inlet gas relative humidity was carried out. Parameters of a Randles-like equivalent circuit were then fitted to the data. In order to improve the quality of the fit, the classical Randles cell was extended by changing the standard plane capacitor into a constant phase element (CPE). It was found that monitoring the evolution of the three resistances of this modified Randles model was an efficient and robust way of monitoring the state-of-health (SOH) of the fuel cell with respect to the water content of the membrane electrode assembly. Moreover, the non-integer power of the CPE was found to be statistically constant over a wide range of operating conditions, thus comforting the assumption that it has a physical meaning. Qualitative interpretation of the variation of the parameters as a function of the SOH is proposed in both flooded and dry conditions. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:905 / 913
页数:9
相关论文
共 22 条
[1]   Study of PEFCs by AC impedance, current interrupt, and dew point measurements - I. Effect of humidity in oxygen gas [J].
Abe, T ;
Shima, H ;
Watanabe, K ;
Ito, Y .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2004, 151 (01) :A101-A105
[2]   Application of measurement models to impedance spectroscopy .3. Evaluation of consistency with the Kramers-Kronig relations [J].
Agarwal, P ;
Orazem, ME ;
GarciaRubio, LH .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1995, 142 (12) :4159-4168
[3]  
BOSCO AD, 2000, Patent No. 6103409
[4]   Experimental analysis of water management in a self-humidifying polymer electrolyte fuel cell stack [J].
Eckl, R ;
Zehtner, W ;
Leu, C ;
Wagner, U .
JOURNAL OF POWER SOURCES, 2004, 138 (1-2) :137-144
[5]  
FENNIE C, 2001, P EVS18
[6]   Analysis of experimental constraints and. variables for time resolved detection of Fourier transform electrochemical impedance spectra [J].
Garland, JE ;
Pettit, CM ;
Roy, D .
ELECTROCHIMICA ACTA, 2004, 49 (16) :2623-2635
[7]  
GIRAULT HH, 2001, PRESSES POLYTECHNIQU
[8]   Study of ionic conductivity profiles of the air cathode of a PEMFC by AC impedance spectroscopy [J].
Guo, QZ ;
Cayetano, M ;
Tsou, YM ;
De Castro, ES ;
White, RE .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2003, 150 (11) :A1440-A1449
[9]   Diagnostic tool to detect electrode flooding in proton-exchange-membrane fuel cells [J].
He, WS ;
Lin, GY ;
Nguyen, TV .
AICHE JOURNAL, 2003, 49 (12) :3221-3228
[10]   Diagnosis of automotive fuel cell power generators [J].
Hissel, D ;
Péra, MC ;
Kauffmann, JM .
JOURNAL OF POWER SOURCES, 2004, 128 (02) :239-246