Validity of peak oxygen uptake calculations from heart rate deflection points

被引:5
作者
deWit, MJP [1 ]
derWeduwe, CJ [1 ]
Wolfhagen, PJJM [1 ]
Hollander, AP [1 ]
机构
[1] VRIJE UNIV AMSTERDAM, FAC HUMAN MOVEMENT SCI, DEPT EXERCISE PHYSIOL & BIOPHYS, AMSTERDAM, NETHERLANDS
关键词
deflection point; heart rate curve; VO(2)peak; cycle ergometer; graded exercise test; Conconi-test; Astrand & Ryhming-test;
D O I
10.1055/s-2007-972620
中图分类号
G8 [体育];
学科分类号
04 [教育学]; 0403 [体育学];
摘要
Two graded exercise tests on a cycle ergometer were examined in regard to their predictability of the peak oxygen uptake ((V) over dot O(2)peak) based upon the deflection points (Dp) in the heart rate curves. The ''constant duration'' test (DUR-test) was based upon data from a previous maximal test. The ''constant distance'' test (DIS-test) was based upon the subjects' body weight and fitness level. In both tests 29 male subjects, 25 to 35 years, pedalled until exhaustion and from these tests the Dp variables (heart rate, DpHR, and the workload, DpW) and the (V) over dot O(2)peak were determined. The subjects also underwent the Astrand & Ryhming-test (A&R-test). Deflection points could be detected for 15 subjects (52 %) in the DUR-test and for 18 subjects (62 %) in the DIS-test. In 13 subjects a Dp in both tests could be determined with a test-retest correlation coefficient of r = 0.66 for the DpHR and r = 0.79 for the DpW. Multiple regression analysis yielded the following equations: (V) over dot O(2)peak = 7.7538 + 0.0199 DpW-0.0506 DpHR (n = 15; r = 0.87; SEE = 0.29 l.min(-1)) for the DUR-test and (V) over dot O(2)peak = 5.8673 + 0.0200 DpW - 0.0354 DpHR (n = 18; r = 0.88; SEE = 0.40 l.min(-1)) for the DIS-test. Compared to the measured (V) over dot O(2)peak of the DUR-test and the DIS-test, the calculated (V) over dot O(2)peak from the A&R-test has a correlation coefficient of r = 0.74 and r = 0.77 with a SEE of 0.57 (13.3 %) and 0.55 (12.7 %) l.min(-1). It was concluded that, when a deflection point in the W-HR curve is found, the (V) over dot O(2)peak can be calculated more accurately with the developed regression equations in this study than with the A&R-test. However, since the graded exercise cycle tests presented in this paper are only reliable in 33 of the 58 cases, they are useless for evaluating the (V) over dot O(2)peak in a practical sense, especially when no previous information about the appearance of a Dp is available.
引用
收藏
页码:201 / 207
页数:7
相关论文
共 38 条
[1]
ASTRAND I, 1960, Acta Physiol Scand Suppl, V49, P1
[2]
A NOMOGRAM FOR CALCULATION OF AEROBIC CAPACITY (PHYSICAL FITNESS) FROM PULSE RATE DURING SUBMAXIMAL WORK [J].
ASTRAND, PO ;
RYHMING, I .
JOURNAL OF APPLIED PHYSIOLOGY, 1954, 7 (02) :218-221
[3]
Astrand PO., 1986, TXB WORK PHYSL
[4]
ADAPTATION OF THE CONCONI TEST TO CHILDREN AND ADOLESCENTS [J].
BALLARIN, E ;
BORSETTO, C ;
CELLINI, M ;
PATRACCHINI, M ;
VITIELLO, P ;
ZIGLIO, PG ;
CONCONI, F .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1989, 10 (05) :334-338
[5]
BINKHORST R A, 1973, Geneeskunde en Sport, V6, P50
[6]
BUNC V, 1984, PRAC LEK, V36, P127
[7]
NONINVASIVE DETERMINATION OF THE ANAEROBIC THRESHOLD IN SWIMMING [J].
CELLINI, M ;
VITIELLO, P ;
NAGLIATI, A ;
ZIGLIO, PG ;
MARTINELLI, S ;
BALLARIN, E ;
CONCONI, F .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1986, 7 (06) :347-351
[8]
DETERMINATION OF THE ANAEROBIC THRESHOLD BY A NON-INVASIVE FIELD-TEST IN RUNNERS [J].
CONCONI, F ;
FERRARI, M ;
ZIGLIO, PG ;
DROGHETTI, P ;
CODECA, L .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 52 (04) :869-873
[10]
DeVries H A, 1965, J Sports Med Phys Fitness, V5, P207