Fabric and elastic principal directions of cancellous bone are closely related

被引:245
作者
Odgaard, A [1 ]
Kabel, J [1 ]
vanRietbergen, B [1 ]
Dalstra, M [1 ]
Huiskes, R [1 ]
机构
[1] UNIV NIJMEGEN, INST ORTHOPAED, BIOMECH SECT, NIJMEGEN, NETHERLANDS
关键词
cancellous bone; trabecular architecture; anisotropy; fabric; FEM;
D O I
10.1016/S0021-9290(96)00177-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Cancellous bone architecture and mechanics are intimately related. The trabecular architecture of cancellous bone is considered determined by its mechanical environment (Wolff's law), and the mechanical properties of cancellous bone are inversely determined by the trabecular architecture and material properties. Much effort has been spent in expressing these relations, but the techniques and variables necessary for this have not been fully identified. It is obvious, however, that some measure of architectural anisotropy (fabric) is needed. Within the last few years, volume-based measures of fabric have been introduced as alternatives to the mean intercept length method, which has some theoretical problems. This paper seeks to answer which of four different fabric measures best predicts finite element calculated mechanical anisotropy directions. Twenty-nine cancellous bone specimens were three-dimensionally reconstructed using the automated serial sectioning technique. A series of large-scale finite-element analyses were performed on each of the three-dimensional reconstructions to calculate the compliance matrix for each specimen, from which the mechanical principal directions were derived. The architectural anisotropy was determined in three-dimensional space for each specimen using mean intercept length (MIL), volume orientation (VO), star volume distribution (SVD) and star length distribution (SLD). Each of the architectural anisotropy results were expressed by a fabric tensor. Architectural main directions were determined from the fabric tensors and compared with the FE-calculated mechanical anisotropy directions. All architectural measures predicted the mechanical main directions rather well, which supports the assumption that mechanical anisotropy directions are aligned with fabric directions. MIL showed a significant, though Very small (1.4 degrees), deviation from the primary mechanical direction. VO had difficulty in determining secondary and tertiary mechanical directions; its mean deviation was 8.9 degrees. SVD and SLD provided marginally better predictors of mechanical anisotropy directions than MIL and VO. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:487 / 495
页数:9
相关论文
共 42 条
[1]  
[Anonymous], 1987, Statistical Analysis of Spherical Data
[2]   WOLFFS LAW OF TRABECULAR ARCHITECTURE AT REMODELING EQUILIBRIUM [J].
COWIN, SC .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (01) :83-88
[3]   THE RELATIONSHIP BETWEEN THE ELASTICITY TENSOR AND THE FABRIC TENSOR [J].
COWIN, SC .
MECHANICS OF MATERIALS, 1985, 4 (02) :137-147
[4]  
Cruz-Orive L.M., 1992, MICRON MICROSC ACTA, V23, P75, DOI DOI 10.1016/0739-6260(92)90076-P
[5]   THE RELATIONSHIP BETWEEN THE STRUCTURAL AND ORTHOGONAL COMPRESSIVE PROPERTIES OF TRABECULAR BONE [J].
GOULET, RW ;
GOLDSTEIN, SA ;
CIARELLI, MJ ;
KUHN, JL ;
BROWN, MB ;
FELDKAMP, LA .
JOURNAL OF BIOMECHANICS, 1994, 27 (04) :375-389
[6]   STEREOLOGICAL ESTIMATION OF THE VOLUME-WEIGHTED MEAN VOLUME OF ARBITRARY PARTICLES OBSERVED ON RANDOM SECTIONS [J].
GUNDERSEN, HJG ;
JENSEN, EB .
JOURNAL OF MICROSCOPY-OXFORD, 1985, 138 (MAY) :127-142
[7]   CHARACTERIZATION OF MICROSTRUCTURAL ANISOTROPY IN ORTHOTROPIC MATERIALS USING A 2ND RANK TENSOR [J].
HARRIGAN, TP ;
MANN, RW .
JOURNAL OF MATERIALS SCIENCE, 1984, 19 (03) :761-767
[8]   LIMITATIONS OF THE CONTINUUM ASSUMPTION IN CANCELLOUS BONE [J].
HARRIGAN, TP ;
JASTY, M ;
MANN, RW ;
HARRIS, WH .
JOURNAL OF BIOMECHANICS, 1988, 21 (04) :269-275
[9]  
Hollister S.J., 1992, Comput. Mech., V10, P73, DOI DOI 10.1007/BF00369853
[10]  
Jacobs C.R., 1993, Bioeng. Conf. ASME BED, P512