A magnification mammography technique using storage phosphor plates: Experimental investigations concerning spatial resolution and detection of microcalcifications.

被引:19
作者
Funke, M
Hermann, KP
Breiter, N
HundertMark, C
Sachs, J
Gruhl, T
Sperner, W
Grabbe, E
机构
[1] UNIV GOTTINGEN, INST MED PHYS & BIOPHYS, D-3400 GOTTINGEN, GERMANY
[2] FIRMA FEINFOCUS, GARBSEN, GERMANY
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1997年 / 167卷 / 02期
关键词
breast radiography; direct magnification; digital radiography;
D O I
10.1055/s-2007-1015512
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Since the routine use of storage phosphor systems for mammography has been limited by its inadequate spatial resolution of 5 linepairs/mm, a combination of a magnification mammography technique with storage phosphor plates was investigated to detect microcalcifications. Material and Methods: A new mammography system with a microfocus tube using an anode of 0.05-0.12 mm allowed to obtain survey views of the breast with 1.7x magnification (m), and spot views with 4x magnification. The digital image receptor comprised a high resolution storage phosphor plate. To determine spatial resolution, contrast transfer curves were obtained, and the detection of microcalcifications was investigated by ROC (receiver operating characteristic) analysis. Results: Spatial resolution for digital survey views (m=1.7) was 8 linepairs/mm and for spot views (m=4) was 18 linepairs/mm. ROC analysis demonstrated a significantly higher performance of the digital magnification technique compared to the conventional screen-film mammography technique, Conclusions: The limitations of digital mammography with respect to spatial resolution can be overcome by using a high magnification technique.
引用
收藏
页码:174 / 179
页数:6
相关论文
共 18 条
[1]   A CLINICAL COMPARISON BETWEEN CONVENTIONAL AND DIGITAL MAMMOGRAPHY UTILIZING COMPUTED RADIOGRAPHY [J].
BRETTLE, DS ;
WARD, SC ;
PARKIN, GJS ;
COWEN, AR ;
SUMSION, HJ .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (797) :464-468
[2]  
CHANG CH, 1992, EUR RADIOL, V2, P483
[3]  
DEWOLF C, 1996, EUROPEAN COMMISSION
[4]  
*DIN, 1990, 6868 DIN
[5]  
DOI K, 1977, RADIOLOGY, V122, P479, DOI 10.1148/122.2.479
[6]   MAXIMUM-LIKELIHOOD ESTIMATION OF PARAMETERS OF SIGNAL-DETECTION THEORY AND DETERMINATION OF CONFIDENCE INTERVALS - RATING-METHOD DATA [J].
DORFMAN, DD ;
ALF, E .
JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1969, 6 (03) :487-&
[7]  
FEIG SA, 1995, RADIOL CLIN N AM, V33, P1205
[8]  
FREEDMAN M, 1993, P SPIE IMAGE CAPTURE, P537
[9]  
FRISCHBIER HJ, 1994, MAMMOGRAPHIE KREBSFR
[10]   MAGNIFICATION MAMMOGRAPHY - EVALUATION OF SCREEN-FILM AND XERORADIOGRAPHIC TECHNIQUES [J].
HAUS, AG ;
PAULUS, DD ;
DODD, GD ;
COWART, RW ;
BENCOMO, J .
RADIOLOGY, 1979, 133 (01) :223-226