De Nova femoropopliteal stenoses: Endovascular gamma irradiation following angioplasty - Angiographic and follow-up in a prospective randomized controlled trial

被引:33
作者
Krueger, K
Zaehringer, M
Bendel, M
Stuetzer, H
Strohe, D
Nolte, M
Wittig, D
Mueller, RP
Lackner, K
机构
[1] Univ Cologne, Dept Radiol, D-50924 Cologne, Germany
[2] Univ Cologne, Dept Radiooncol, D-50924 Cologne, Germany
[3] Univ Cologne, Inst Med Stat Informat & Epidemiol, D-50924 Cologne, Germany
关键词
arteries; radiation; restenosis; stenosis or obstruction; transluminal angioplasty; iridium; radioactive;
D O I
10.1148/radiol.2312030421
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess and report the follow-up results of a randomized controlled trial on centered enclovascular gamma irradiation performed after percutaneous transluminal angioplasty (PTA) for de novo femoropopliteal stenoses. MATERIALS AND METHODS: Thirty patients who underwent PTA for de novo femoropopliteal stenoses were randomly assigned to undergo 14-Gy centered enclovascular irradiation (irradiation group, n = 15) or no irradiation (control group, n = 15). Intraarterial angiography was performed 6, 12, and 24 months after treatment; duplex ultrasonography (US), the day before and after PTA and 1, 3, 6, 9, 12, 18, and 24 months later. Treadmill tests and interviews were performed the day before PTA and 1, 3, 6, 9, 12, 18 and 24 months later. Results of angiography, duplex US, treadmill tests, and interviews were evaluated with the nonpaired t or the Fisher exact test. RESULTS: Baseline characteristics did not differ significantly between the two groups. Mean absolute individual changes in degree of stenosis, compared with the degrees of stenosis shortly after PTA, in the irradiation group versus in the control group were -10.6% +/- 22.3 versus 39.6% +/- 24.6 (P < .001) at 6 months, -2.0% +/- 34.2 versus 40.6% +/- 32.6 (P = .002) at 12 months, and 7.4% +/- 43.2 versus 37.7% +/- 34.5 (P = .043) at 24 months. The rates of target lesion restenosis at 6 (P = .006) and 12 (P = .042) months were significantly lower in the irradiation group. The numbers of target lesion re-treatments were similar between the groups, but target vessel re-treatments were more frequent in the irradiation group. There were no significant differences in interview or treadmill test results between the two groups at t test analysis. CONCLUSION: The degree of stenosis was significantly reduced 6, 12, and 24 months after angioplasty of de novo femoropopliteal stenoses in the patients who underwent enclovascular irradiation. (C) RSNA, 2004.
引用
收藏
页码:546 / 554
页数:9
相关论文
共 37 条
[1]   Edge restenosis after implantation of high activity 32P radioactive β-emitting stents [J].
Albiero, R ;
Nishida, T ;
Adamian, M ;
Amato, A ;
Vaghetti, M ;
Corvaja, N ;
Di Mario, C ;
Colombo, A .
CIRCULATION, 2000, 101 (21) :2454-2457
[2]   Late coronary occlusion after intracoronary brachytherapy [J].
Costa, MA ;
Sabaté, M ;
van der Giessen, WJ ;
Kay, IP ;
Cervinka, P ;
Ligthart, JMR ;
Serrano, P ;
Coen, VLMA ;
Levendag, PC ;
Serruys, PW .
CIRCULATION, 1999, 100 (08) :789-792
[3]   The role of radiation therapy in the management of vascular restenosis. Part II. Radiation techniques and results [J].
Diamond, DA ;
Vesely, TM .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (03) :389-400
[4]  
*FOOD DRUG ADM, MED DEV APPR
[5]   Five-year clinical follow-up after intracoronary radiation - Results of a randomized clinical trial [J].
Grise, MA ;
Massullo, V ;
Jani, S ;
Popma, JJ ;
Russo, RJ ;
Schatz, RA ;
Guarneri, EM ;
Steuterman, S ;
Cloutier, DA ;
Leon, MB ;
Tripuraneni, P ;
Teirstein, PS .
CIRCULATION, 2002, 105 (23) :2737-2740
[6]   Intracoronary β-irradiation with a liquid 188Re-filled balloon -: Six-month results from a clinical safety and feasibility study [J].
Höher, M ;
Wöhrle, J ;
Wohlfrom, M ;
Hanke, H ;
Voisard, R ;
Osterhues, HH ;
Kochs, M ;
Reske, SN ;
Hombach, V ;
Kotzerke, J .
CIRCULATION, 2000, 101 (20) :2355-2360
[7]   FEMORAL AND POPLITEAL ARTERIES - REANALYSIS OF RESULTS OF BALLOON ANGIOPLASTY [J].
JOHNSTON, KW .
RADIOLOGY, 1992, 183 (03) :767-771
[8]   Endovascular gamma irradiation of femoropopliteal de novo stenoses immediately after PTA: Interim results of prospective randomized controlled trial [J].
Krueger, K ;
Landwehr, P ;
Bendel, M ;
Nolte, M ;
Stuetzer, H ;
Bongartz, R ;
Zaehringer, M ;
Winnekendonk, G ;
Gossmann, A ;
Mueller, RP ;
Lackner, K .
RADIOLOGY, 2002, 224 (02) :519-528
[9]   Endovascular gamma-irradiation for prevention or restenosis after angioplasty of femoropopliteal de-novo-stenoses-long-term results of a feasibility study [J].
Krüger, K ;
Bendel, M ;
Zähringer, M ;
Bongartz, R ;
Nolte, M ;
Schulte, O ;
Lackner, K .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (03) :321-327
[10]   Quantitative angiographic analysis of stent restenosis in the Scripps Coronary Radiation to Inhibit Initial Proliferation Post Stenting (SCRIPPS) trial [J].
Lansky, AJ ;
Popma, JJ ;
Massullo, V ;
Jani, S ;
Russo, RJ ;
Schatz, RA ;
Steuterman, S ;
Guarneri, EM ;
Wu, HS ;
Mehran, R ;
Mintz, GS ;
Leon, MB ;
Teirstein, PS .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (04) :410-414