Scaling and the design of miniaturized chemical-analysis systems

被引:576
作者
Janasek, Dirk [1 ]
Franzke, Joachim [1 ]
Manz, Andreas [1 ]
机构
[1] ISAS, Inst Analyt Sci, D-44139 Dortmund, Germany
关键词
FREE-FLOW ELECTROPHORESIS; VOLATILE ORGANIC-COMPOUNDS; TRAP MASS-SPECTROMETER; CAPILLARY-ELECTROPHORESIS; SEPARATION; MICROCHIP; CHROMATOGRAPHY; PERFORMANCE; RESOLUTION; DEVICE;
D O I
10.1038/nature05059
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Micrometre-scale analytical devices are more attractive than their macroscale counterparts for various reasons. For example, they use smaller volumes of reagents and are therefore cheaper, quicker and less hazardous to use, and more environmentally appealing. Scaling laws compare the relative performance of a system as the dimensions of the system change, and can predict the operational success of miniaturized chemical separation, reaction and detection devices before they are fabricated. Some devices designed using basic principles of scaling are now commercially available, and opportunities for miniaturizing new and challenging analytical systems continue to arise.
引用
收藏
页码:374 / 380
页数:7
相关论文
共 68 条
[1]  
ALBRECHT J, 2005, 9 INT C MIN SYST CHE, P1537
[2]   Improved resolution with microchip-based enhanced field inversion electrophoresis [J].
Backhouse, CJ ;
Gajdal, A ;
Pilarski, LM ;
Crabtree, HJ .
ELECTROPHORESIS, 2003, 24 (11) :1777-1786
[3]   Cylindrical ion trap array with mass selection by variation in trap dimensions [J].
Badman, ER ;
Cooks, RG .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :5079-5086
[4]   Miniaturized EI/Q/oa TOF mass spectrometer [J].
Berkout, VD ;
Cotter, RJ ;
Segers, DP .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (06) :641-647
[5]   Microstructure for efficient continuous flow mixing [J].
Bessoth, FG ;
deMello, AJ ;
Manz, A .
ANALYTICAL COMMUNICATIONS, 1999, 36 (06) :213-215
[6]   Towards the hand-held mass spectrometer: design considerations, simulation, and fabrication of micrometer-scaled cylindrical ion traps [J].
Blain, MG ;
Riter, LS ;
Cruz, D ;
Austin, DE ;
Wu, GX ;
Plass, WR ;
Cooks, RG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 236 (1-3) :91-104
[7]   Trade-offs in miniature quadrupole designs [J].
Boumsellek, S ;
Ferran, RJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (06) :633-640
[8]   ELECTRICALLY DRIVEN OPEN-TUBULAR LIQUID-CHROMATOGRAPHY [J].
BRUIN, GJM ;
TOCK, PPH ;
KRAAK, JC ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1990, 517 :557-572
[10]  
Cornish TJ, 2000, RAPID COMMUN MASS SP, V14, P2408, DOI 10.1002/1097-0231(20001230)14:24<2408::AID-RCM181>3.0.CO