Determination of chlorogenic acid and rutin in cigarettes by an improved capillary electrophoresis indirect chemiluminescence system

被引:51
作者
Jiang, HL [1 ]
He, YZ [1 ]
Zhao, HZ [1 ]
Hu, YY [1 ]
机构
[1] Univ Sci & Technol China, Dept Chem, Hefei 230026, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
chemiluminescence; capillary; liquid chromatography;
D O I
10.1016/j.aca.2004.02.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An improved capillary electrophoresis indirect chemiluminescence system was employed for the determination of chlorogenic acid and rutin in cigarette samples. After being separated by capillary electrophoresis, the analyte zones were determined by indirect chemiluminescence of luminol-potassium hexacyanoferrate. In this system, luminol was added into running buffer solution and introduced at the head of separation capillary, and potassium hexacyanoferrate was introduced at the end of the capillary. A high potential buffer reservoir was constructed from a running buffer cell and an electrode buffer one, which were jointed with a frit, in order to avoid luminol electrolysis in high potential reservoir and the excursion of chemiluminescence baseline. A low potential flow reservoir was used to prevent electrode buffer solution from the contamination of chemiluminescence waste. Therefore, the proposed capillary electrophoresis-chemiluminescence system can avoid the electrolysis of chemiluminescence reagent, retain the stability of chemiluminescence baseline and prolong the working time of running and electrode buffer solutions. In addition, the matrix of cigarette sample solutions has also an inhibitory effect on the chemiluminescence intensity in the indirect detection, whereas the influence was not observed in the separation of standard solutions. After the correction of matrix inhibition and the calibration with standard addition method, chlorogenic acid and rutin were determined in four cigarette samples by the improved capillary electrophoresis-chemiluminescence system. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:111 / 119
页数:9
相关论文
共 51 条
[1]   IDENTIFICATION AND DETERMINATION OF PHENOLIC CONSTITUENTS IN NATURAL BEVERAGES AND PLANT-EXTRACTS BY MEANS OF A COULOMETRIC ELECTRODE ARRAY SYSTEM [J].
ACHILLI, G ;
CELLERINO, GP ;
GAMACHE, PH ;
DERIL, GVM .
JOURNAL OF CHROMATOGRAPHY, 1993, 632 (1-2) :111-117
[2]   Determination of anti-carcinogenic polyphenols present in green tea using capillary electrophoresis coupled to a flow injection system [J].
Arce, L ;
Ríos, A ;
Valcárcel, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 827 (01) :113-120
[3]   Determination of trans-resveratrol and other polyphenols in wines by a continuous flow sample clean-up system followed by capillary electrophoresis separation [J].
Arce, L ;
Tena, MT ;
Rios, A ;
Valcárcel, M .
ANALYTICA CHIMICA ACTA, 1998, 359 (1-2) :27-38
[4]   Determination of codeine, 6-methoxycodeine and thebaine using capillary electrophoresis with tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW ;
Purcell, SD .
ANALYTICAL COMMUNICATIONS, 1998, 35 (10) :321-324
[5]   Determination of morphine, oripavine and pseudomorphine using capillary electrophoresis with acidic potassium permanganate chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW .
ANALYST, 2000, 125 (01) :91-95
[6]   HIGH-PERFORMANCE REVERSED-PHASE LIQUID-CHROMATOGRAPHY OF NATURALLY OCCURRING PHENOLIC COMPOUNDS [J].
COURT, WA .
JOURNAL OF CHROMATOGRAPHY, 1977, 130 (JAN11) :287-291
[7]   Determination of polyphenols by high-performance liquid chromatography with inhibited chemiluminescence detection [J].
Cui, H ;
He, CX ;
Zhao, GW .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :171-179
[8]   END-COLUMN CHEMILUMINESCENCE DETECTOR FOR CAPILLARY ELECTROPHORESIS [J].
DADOO, R ;
SETO, AG ;
COLON, LA ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :303-306
[9]  
Dadoo R., 1992, J HIGH RES CHROMATOG, V15, P133
[10]  
DENG GC, 1996, CHINESE J ANAL CHEM, V24, P1312