Stress versus strain relationship of high strength concrete under high lateral confinement

被引:52
作者
Candappa, DP [1 ]
Setunge, S [1 ]
Sanjayan, JG [1 ]
机构
[1] Monash Univ, Dept Civil Engn, Clayton, Vic 3168, Australia
关键词
compressive strength; mechanical properties; high performance concrete; modeling; stress-strain curve;
D O I
10.1016/S0008-8846(99)00219-7
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A common application of high strength concrete (HSC) is in columns subjected to large compressive forces. However, a major problem is the insufficient ductility available in HSC columns. To determine the required lateral reinforcement to maintain sufficient ductility, a good understanding of the stress-strain behaviour of confined concrete needs to be established. This paper describes a testing program carried nut to obtain experimental data of complete (ascending and descending) stress-strain relationships between axial stress, axial strain and lateral strain for HSC. Compressive strengths of concrete tested were 100 MPa and 60 MPa. The confining pressures used were 4 MPa, 8 MPa and 12 MPa. A total of 18 stress-strain curves are presented. The experimental results obtained seem to indicate that, for high confining pressures, the lateral strain at peak stress for 100 MPa concrete was 20% less than that of the 60 MPa concrete. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1977 / 1982
页数:6
相关论文
共 4 条
[1]  
AHMAD SH, 1985, PCI J, V30, P92
[2]  
CANDAPPA DP, 1996, P 21 C OUR WORLD CON, P77
[3]  
DAHL KKB, 1992, CALIBRATION USE TR R, P285
[4]  
NEVILLE AM, 1992, CONCRETE TECHNOLOGY