Development of a fluorescence polarization immunoassay for lorazepam quantification

被引:6
作者
Agbuya, PG
Li, L
Miles, MV
Zaritsky, AL
Morris, AD
机构
[1] EASTERN VIRGINIA MED SCH,CTR PEDIAT RES,NORFOLK,VA 23510
[2] CHILDRENS HOSP KINGS DAUGHTERS,DEPT PEDIAT,DIV CRIT CARE MED,NORFOLK,VA
[3] OLD DOMINION UNIV,DEPT CHEM & BIOCHEM,NORFOLK,VA
关键词
lorazepam; benzodiazepine; fluorescence polarization immunoassay; analysis;
D O I
10.1097/00007691-199604000-00014
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Lorazepam concentrations have been quantified in biological fluids using gas chromatography and high-performance liquid chromatography (HPLC). However, these methods are too time consuming and labor intensive for most nonresearch laboratories to offer. A fluorescence polarization immunoassay (FPIA) method for quantification of lorazepam was developed and validated using a reverse-phase HPLC method as the reference method. The FPIA method involves a single liquid-liquid extraction of 100 mu l of either serum or plasma, then direct analysis using the TDxFLx (Abbott Diagnostics, North Chicago, IL). FPIA calibrations were linear between 50 and 800 ng/ml using five calibrators prepared in human serum. Within-run precision (n = 10) for three serum controls (75, 300, and 600 ng/ml) resulted in coefficients of variation (CVs) of 5.7%, 5.4%, and 4.2%, respectively. Between-day precision studies for the three serum controls were 7.0%, 8.9% and 4.9%, respectively (n = 5). The analytical recovery of the three serum controls was 104.9%, 97.3% and 98.3%, respectively. There was an excellent linear correlation between the FPIA and HPLC determinations of 43 patient specimens (r = 0.990, slope = 0.961, intercept = 16.3). No interferences were found from many commonly prescribed nonbenzodiazepine drugs; however, other benzodiazepines that were tested will cross-react with this procedure and give inaccurate results. Therefore, this method should not be used in patients who are receiving other benzodiazepines in addition to lorazepam. The FPIA method described herein can be adapted to reliably measure lorazepam concentrations in serum or plasma.
引用
收藏
页码:194 / 199
页数:6
相关论文
共 22 条
  • [1] ORAL PREMEDICATION IN CHILDREN - A COMPARISON OF CHLORAL HYDRATE, DIAZEPAM, ALPRAZOLAM, MIDAZOLAM AND PLACEBO FOR DAY SURGERY
    ANDERSON, BJ
    EXARCHOS, H
    LEE, K
    BROWN, TCK
    [J]. ANAESTHESIA AND INTENSIVE CARE, 1990, 18 (02) : 185 - 193
  • [2] AWNI WM, 1989, CLIN CHEM, V25, P2124
  • [3] PLASMA-CONCENTRATIONS AND CLINICAL EFFECTS OF LORAZEPAM AFTER ORAL-ADMINISTRATION
    BRADSHAW, EG
    ALI, AA
    MULLEY, BA
    RYE, RM
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1981, 53 (05) : 517 - 522
  • [4] BURTIS CA, 1994, TIETZ TXB CLIN CHEM, P2214
  • [5] AGE-RELATED DIFFERENCES IN HEPATIC DRUG CLEARANCE IN CHILDREN - STUDIES WITH LORAZEPAM AND ANTIPYRINE
    CROM, WR
    RELLING, MV
    CHRISTENSEN, ML
    RIVERA, GK
    EVANS, WE
    [J]. CLINICAL PHARMACOLOGY & THERAPEUTICS, 1991, 50 (02) : 132 - 140
  • [6] CRONIN CMG, 1992, PEDIATRICS, V89, P1129
  • [7] DETERMINATION OF LORAZEPAM IN PLASMA BY ELECTRON-CAPTURE GLC
    DEGROOT, G
    MAES, RAA
    LEMMENS, HHJ
    [J]. ARCHIVES OF TOXICOLOGY, 1976, 35 (03) : 229 - 234
  • [8] LORAZEPAM ANALYSIS USING LIQUID-CHROMATOGRAPHY - IMPROVED SENSITIVITY FOR SINGLE-DOSE PHARMACOKINETIC STUDIES
    EGAN, JM
    ABERNETHY, DR
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 380 (01): : 196 - 201
  • [9] METABOLISM OF LORAZEPAM
    ELLIOTT, HW
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1976, 48 (10) : 1017 - 1023
  • [10] ANALYSIS OF LORAZEPAM AND ITS GLUCURONIDE METABOLITE BY ELECTRON-CAPTURE GAS-LIQUID-CHROMATOGRAPHY - USE IN PHARMACOKINETIC STUDIES OF LORAZEPAM
    GREENBLATT, DJ
    FRANKE, K
    SHADER, RI
    [J]. JOURNAL OF CHROMATOGRAPHY, 1978, 146 (02): : 311 - 320