Countercurrent double-pipe heat exchanger subjected to flow-rate step change, part II: Analytical and experimental transient response

被引:13
作者
Abdelghani-Idrissi, MA [1 ]
Bagui, F
Estel, I
机构
[1] Univ Rouen, IUT Genie Therm & Energie, F-76821 Mont St Aignan, France
[2] INSA, LRCP, Mont St Aignan, France
关键词
D O I
10.1080/01457630290090617
中图分类号
O414.1 [热力学];
学科分类号
摘要
This article investigates the analytical time constants of temperatures transient response along a countercurrent heat exchanger when a mass flow-rate step change is applied on hot fluid flowing through the inner duct. The time constants of the hot and cold fluids are spatially linear and the fluid not submitted to step change shows two types of transient response. The first corresponds to a linear spatial decreasing of the time constant, while the second presents a uniform time constant along the heat exchanger. For each case, the analytical expressions of time constants are derived taking the conditions of the transient response on the boundaries of the heat exchanger. The condition which enables distinguishing the two cases is also proposed in this article. The comparison between theoretical and experimental results allows us to validate the analytical expressions, which depend on the initial and final steady states. The influence of the magnitude of flow-rate step change on the transient behavior is studied by maintaining the initial steady state. In the same way, the initial steady-state effect is investigated with the same magnitude of the flow-rate step change. The comparison of response time to positive and negative flow-rate step change is also presented for different values of cold-fluid flow rate.
引用
收藏
页码:12 / 24
页数:13
相关论文
共 14 条
[1]  
ABDELGHANI MA, 2002, HEAT TRANSFER ENG, V23
[2]  
AZILINON D, 1990, REV GEN THERM, V29, P64
[3]  
FRAGNAUD F, 1997, UNSTEADY HEAT TRANSF, P329
[4]  
GOGUS YA, 1997, TRANSIENT CONVECTIVE, P289
[5]   CHARACTERIZATION OF THE RESPONSE OF A THERMAL EXCHANGER WHEN SUBMITTED TO SIMULTANEOUS STEPS IN TEMPERATURE [J].
HADIDI, M ;
GUELLAL, M ;
LACHI, M ;
PADET, J .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1995, 22 (01) :145-154
[6]  
HADIDI M, 1993, C INT FRANC THERM SY, P139
[7]   TRANSIENT-BEHAVIOR OF VARIOUS TYPES OF HEAT-EXCHANGERS - MODELS AND IMPLICATIONS [J].
HENRION, M ;
FEIDT, M .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1991, 18 (05) :731-740
[8]   The time constant of double pipe and one pass shell-and-tube heat exchangers in the case of varying fluid flow rates [J].
Lachi, M ;
ElWakil, N ;
Padet, J .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1997, 40 (09) :2067-2079
[9]  
LACHI M, 1995, C INT FRANC THERM SY, P139
[10]   DYNAMIC SIMULATION OF A COUNTERCURRENT HEAT-EXCHANGER MODELING-START-UP AND FREQUENCY-RESPONSE [J].
LAKSHMANAN, CC ;
POTTER, OE .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1994, 21 (03) :421-434