Ultrasound-guided central venous cannulation in infants and children

被引:67
作者
Åsheim, P [1 ]
Mostad, U [1 ]
Aadahl, P [1 ]
机构
[1] Univ Trondheim Hosp, Dept Anesthesia & Intens Care, N-7006 Trondheim, Norway
关键词
central venous catheter; children; external landmark technique; infants; ultrasound-guided technique;
D O I
10.1034/j.1399-6576.2002.460410.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Percutaneous central venous cannulation in infants and children is a challenging procedure. Traditionally, an external landmark technique has been used to identify puncture site. An ultrasound-guided technique is now available and we wanted to evaluate this method in children and infants, looking specifically at the ease of use, success rate and complications. Methods: Forty-two consecutive infants and children (median 16.5 [0-177] months and 10 [3-45] kg) scheduled for central venous catheter placement were registered. An ultrasound scanner made for guiding puncture of vessels was used. After locating the puncture site, a sterile procedure was performed using an accompanying kit to aid puncture of the vessel. Results: Cannulation was successful in all patients and we had no complications during insertion of the catheters. The right internal jugular vein was preferred in most patients, and in 95% of the patients the vein was punctured at the first attempt. The median time from start of puncture to aspiration of blood was 12 (3-180) seconds. Conclusion: The ultrasound-guided technique for placement of central venous catheters was easy to apply in infants and children. It is our impression that it increased the precision and safety of the procedure in this group of patients. (C) Acta Anaesthesiologica Scandinavica 46 (2002).
引用
收藏
页码:390 / 392
页数:3
相关论文
共 7 条
[1]   ULTRASOUND-ASSISTED CANNULATION OF THE INTERNAL JUGULAR-VEIN - A PROSPECTIVE COMPARISON TO THE EXTERNAL LANDMARK-GUIDED TECHNIQUE [J].
DENYS, BG ;
URETSKY, BF ;
REDDY, PS .
CIRCULATION, 1993, 87 (05) :1557-1562
[2]   Complications and risks of central venous catheter placement in children [J].
Johnson, EM ;
Saltzman, DA ;
Suh, G ;
Dahms, RA ;
Leonard, AS .
SURGERY, 1998, 124 (05) :911-916
[3]   Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature [J].
Randolph, AG ;
Cook, DJ ;
Gonzales, CA ;
Pribble, CG .
CRITICAL CARE MEDICINE, 1996, 24 (12) :2053-2058
[4]   Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography [J].
Troianos, CA ;
Kuwik, RJ ;
Pasqual, JR ;
Lim, AJ ;
Odasso, DP .
ANESTHESIOLOGY, 1996, 85 (01) :43-48
[5]  
Verghese S, 1996, ANESTHESIOLOGY, V85, pA1078
[6]   Comparison of three techniques for internal jugular vein cannulation in infants [J].
Verghese, ST ;
McGill, WA ;
Patel, RI ;
Sell, JE ;
Midgley, FM ;
Ruttimann, UE .
PAEDIATRIC ANAESTHESIA, 2000, 10 (05) :505-511
[7]   Ultrasound-guided internal jugular venous cannulation in infants - A prospective comparison with the traditional palpation method [J].
Verghese, ST ;
McGill, WA ;
Patel, RI ;
Sell, JE ;
Midgley, FM ;
Ruttimann, UE .
ANESTHESIOLOGY, 1999, 91 (01) :71-77