Sample-induced RF perturbations in high-field, high-resolution NMR spectroscopy

被引:18
作者
Crozier, S
Brereton, IM
Zelaya, FO
Roffmann, WU
Doddrell, DM
机构
[1] Centre for Magnetic Resonance, University of Queensland, St. Lucia
基金
澳大利亚研究理事会;
关键词
D O I
10.1006/jmre.1997.1119
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Conducting dielectric samples are often used in high-resolution experiments at high held. It is shown that significant amplitude and phase distortions of the RF magnetic field may result from perturbations caused by such samples. Theoretical analyses demonstrate the spatial variation of the RF field amplitude and phase across the sample, and comparisons of the effect are made for a variety of sample properties and operating field strengths. Although the effect is highly nonlinear, it tends to increase with increasing field strength, permittivity, conductivity, and sample size. There are cases, however, in which increasing the conductivity of the sample improves the homogeneity of the amplitude of the RF field across the sample at the expense of distorted RF phase. It is important that the perturbation effects be calculated for the experimental conditions used, as they have the potential to reduce the signal-to-noise ratio of NMR experiments and may increase the generation of spurious coherences. The effect of RF-coil geometry on the coherences is also modeled, with the use of homogeneous resonators such as the birdcage design being preferred, Recommendations are made concerning methods of reducing sample-induced perturbations. Experimental high-field imaging and high-resolution studies demonstrate the effect. (C) 1997 Academic Press.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 15 条
[1]  
Balanis C.A., 2012, Advanced Engineering Electromagnetics, Vsecond
[2]   RF MAGNETIC-FIELD PENETRATION, PHASE-SHIFT AND POWER DISSIPATION IN BIOLOGICAL TISSUE - IMPLICATIONS FOR NMR IMAGING [J].
BOTTOMLEY, PA ;
ANDREW, ER .
PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (04) :630-643
[3]   ESTIMATING RADIOFREQUENCY POWER DEPOSITION IN BODY NMR IMAGING [J].
BOTTOMLEY, PA ;
REDINGTON, RW ;
EDELSTEIN, WA ;
SCHENCK, JF .
MAGNETIC RESONANCE IN MEDICINE, 1985, 2 (04) :336-349
[4]   OPTIMIZED SMALL-BORE, HIGH-PASS RESONATOR DESIGNS [J].
CROZIER, S ;
LUESCHER, K ;
FORBES, LK ;
DODDRELL, DM .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1995, 109 (01) :1-11
[5]   REDUCTION OF RF PENETRATION EFFECTS IN HIGH-FIELD IMAGING [J].
FOO, TKF ;
HAYES, CE ;
KANG, YW .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :287-301
[6]   COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING [J].
GLOVER, GH ;
HAYES, CE ;
PELC, NJ ;
EDELSTEIN, WA ;
MUELLER, OM ;
HART, HR ;
HARDY, CJ ;
ODONNELL, M ;
BARBER, WD .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) :255-270
[7]   AN EFFICIENT, HIGHLY HOMOGENEOUS RADIOFREQUENCY COIL FOR WHOLE-BODY NMR IMAGING AT 1.5-T [J].
HAYES, CE ;
EDELSTEIN, WA ;
SCHENCK, JF ;
MUELLER, OM ;
EASH, M .
JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (03) :622-628
[8]   The measurement of the conductance of electrolytes V. A redetermination of the conductance of standard potassium chloride solutions in absolute units [J].
Jones, G ;
Bradshaw, BC .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1933, 55 :1780-1800
[9]   ELECTRIC-FIELD MEASUREMENTS IN CYLINDRICAL IMAGING COILS [J].
JOSEPH, PM ;
SAADIELMANDJRA, M .
JOURNAL OF MAGNETIC RESONANCE, 1987, 75 (02) :199-212
[10]  
MANSFIELD P, 1982, ADV MAGNETIC RESON S, V2, P181