Roof-harvested rainwater for potable purposes: application of solar disinfection (SODIS) and limitations

被引:30
作者
Amin, Muhammad Tahir [1 ]
Han, Mooyoung [2 ]
机构
[1] Seoul Natl Univ, Coll Engn, Civil & Environm Engn Dept 39 217, Seoul 151742, South Korea
[2] Seoul Natl Univ, Civil & Environm Engn Dept 38 206, Seoul 151742, South Korea
关键词
coliform; PET; potability; rainwater; SODIS; DRINKING-WATER; SUNLIGHT INACTIVATION; INDICATOR BACTERIA; BACTERIOPHAGES; REFLECTORS; SURVIVAL; BOTTLES; PH;
D O I
10.2166/wst.2009.347
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Efficiency of solar disinfection (SODIS) was evaluated for the potability of rainwater in view of the increasing water and energy crises especially in developing countries. Rainwater samples were collected from an underground storage tank in 2 L polyethylene terephthalate (PET) bottles and SODIS efficiency was evaluated at different weather conditions. For optimizing SODIS, PET bottles with different backing surfaces to enhance the optical and thermal effects of SODIS were used and different physicochemical parameters were selected and evaluated along with microbial re-growth observations and calculating microbial decay constants. Total and fecal coliforms were used along with Escherichia Coli and Heterotrophic Plate Counts (HPC) as basic microbial and indicator organisms of water quality. For irradiance less than 600W/m(2), reflective type PET bottles were best types while for radiations greater than 700W/m(2), absorptive type PET bottles offered best solution due to the synergistic effects of both thermal and UV radiations. Microbial inactivation did not improve significantly by changing the initial pH and turbidity values but optimum SODIS efficiency is achieved for rainwater with acidic pH and low initial turbidity values by keeping air-spaced PET bottles in undisturbed conditions. Microbial re-growth occurred after one day only at higher turbidity values and with basic pH values. First-order reaction rate constant was in accordance with recent findings for TC but contradicted with previous researches for E. coli. No microbial parameter met drinking water guidelines even under strong experimental weather conditions rendering SODIS ineffective for complete disinfection and hence needed more exposure time or stronger sunlight radiations. With maximum possible storage of rainwater, however, and by using some means for accelerating SODIS process, rainwater can be disinfected and used for potable purposes.
引用
收藏
页码:419 / 431
页数:13
相关论文
共 23 条
[1]  
Acra A., 1984, Solar disinfection of drinking water and oral rehydration solutions: Guidelines for household application in developing countries
[2]  
[Anonymous], 1999, Standard Methods for Examination of Water and Waste Water
[3]  
Cooper A., 1998, J ADV OXIDATION TECH, V3, P151
[4]   INFLUENCE OF PH, OXYGEN, AND HUMIC SUBSTANCES ON ABILITY OF SUNLIGHT TO DAMAGE FECAL-COLIFORMS IN WASTE STABILIZATION POND WATER [J].
CURTIS, TP ;
MARA, DD ;
SILVA, SA .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1992, 58 (04) :1335-1343
[5]  
Dan TBB, 1997, WATER RES, V31, P2755
[6]  
Foegeding E.A., 1996, Food Chemistry, P879
[7]  
Goswami D. J., 1997, SOLAR ENERGY ENG, V119, P101
[8]  
Goswami D.Y., 1995, ADV SOLAR ENERGY ASE, P165
[9]   Particle behaviour consideration to maximize the settling capacity of rainwater storage tanks [J].
Han, M. Y. ;
Mun, J. S. .
WATER SCIENCE AND TECHNOLOGY, 2007, 56 (11) :73-79
[10]  
Han M.Y., 2007, WATER, V21, P47