Enhancing the precision of ECG baseline correction: Selective filtering and removal of residual error

被引:41
作者
Shusterman, V [1 ]
Shah, SI [1 ]
Beigel, A [1 ]
Anderson, KP [1 ]
机构
[1] Univ Pittsburgh, UPHS, Cardiovasc Inst, Pittsburgh, PA 15213 USA
来源
COMPUTERS AND BIOMEDICAL RESEARCH | 2000年 / 33卷 / 02期
关键词
electrocardiogram; baseline wander; selective filtering; residual error;
D O I
10.1006/cbmr.2000.1539
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Reemergence of the problem of baseline correction is related to recent advancements in the electrocardiographic (ECG) analysis of brat-to-beat repolarization changes which play an important role in risk assessment and the prediction of sudden cardiac death. These alterations often have an amplitude of a few microvolts and duration of several milliseconds and their detection requires special accuracy of baseline estimation. Using detailed analysis of various types of residual errors we designed a two-step procedure for selective filtering of ECG and removal of residual error with minimal distortion of cardiac complexes and tested this approach on 100 simulated and 210 real ECG signals. Application of this procedure provided a twofold reduction in the error of baseline estimation and T-wave amplitude measurements compared to high-pass filtering. Selective application of this approach to the segments with low baseline drift allowed analysis of low-amplitude, beat-to-beat changes in repolarization during more than 70% of the recording time, (C) 2000 Academic Press.
引用
收藏
页码:144 / 160
页数:17
相关论文
共 22 条
[1]  
AHSTROM ML, 1985, IEEE T BIOMED ENG, V32, P708
[2]  
BADILINI F, 1991, C IEEE ENG MED BIOL, P13
[3]   RECOMMENDATIONS FOR STANDARDIZATION AND SPECIFICATIONS IN AUTOMATED ELECTROCARDIOGRAPHY - BANDWIDTH AND DIGITAL SIGNAL-PROCESSING - A REPORT FOR HEALTH-PROFESSIONALS BY AN AD HOC WRITING GROUP OF THE COMMITTEE ON ELECTROCARDIOGRAPHY AND CARDIAC ELECTROPHYSIOLOGY OF THE COUNCIL-ON-CLINICAL-CARDIOLOGY, AMERICAN-HEART-ASSOCIATION [J].
BAILEY, JJ ;
BERSON, AS ;
GARSON, A ;
HORAN, LG ;
MACFARLANE, PW ;
MORTARA, DW ;
ZYWIETZ, C .
CIRCULATION, 1990, 81 (02) :730-739
[4]  
DEPINTO V, 1991, J ELECTROCARDIOL S, V25, P40
[5]   A FILTER TO SUPPRESS ECG BASE-LINE WANDER AND PRESERVE ST-SEGMENT ACCURACY IN A REAL-TIME ENVIRONMENT [J].
FRANKEL, RA ;
POTTALA, EW ;
BOWSER, RW ;
BAILEY, JJ .
JOURNAL OF ELECTROCARDIOLOGY, 1991, 24 (04) :315-323
[6]   A COMPARISON OF THE NOISE SENSITIVITY OF 9 QRS DETECTION ALGORITHMS [J].
FRIESEN, GM ;
JANNETT, TC ;
JADALLAH, MA ;
YATES, SL ;
QUINT, SR ;
NAGLE, HT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) :85-98
[7]  
Gradwohl Jake R., 1988, P COMP CARD 1988 IEE, P493
[8]   CLINICAL-APPLICATIONS OF BODY-SURFACE POTENTIAL MAPPING [J].
GREEN, LS ;
ABILDSKOV, JA .
CLINICAL CARDIOLOGY, 1995, 18 (05) :245-249
[9]   THE LONG QT SYNDROMES - A CRITICAL-REVIEW, NEW CLINICAL OBSERVATIONS AND A UNIFYING HYPOTHESIS [J].
JACKMAN, WM ;
FRIDAY, KJ ;
ANDERSON, JL ;
ALIOT, EM ;
CLARK, M ;
LAZZARA, R .
PROGRESS IN CARDIOVASCULAR DISEASES, 1988, 31 (02) :115-172
[10]  