Oxygen Therapeutics: Perfluorocarbons and Blood Substitute Safety

被引:64
作者
Cohn, Claudia S. [2 ]
Cushing, Melissa M. [1 ]
机构
[1] Weill Cornell Med Coll, Dept Pathol, New York, NY 10065 USA
[2] New York Presbyterian Hosp Weill Cornell, Dept Pathol, New York, NY 10065 USA
关键词
Blood substitute; Perfluorocarbons (PFC); Hemoglobin-based-oxygen-carrier (HBOC); POLYMERIZED BOVINE HEMOGLOBIN; CO-OXIMETRY INTERFERENCE; CROSS-LINKED HEMOGLOBIN; CELL-FREE HEMOGLOBIN; PERFLUBRON EMULSION; LABORATORY TESTS; IN-VITRO; CARRIERS; COAGULATION; SURGERY;
D O I
10.1016/j.ccc.2008.12.007
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Current demands over the blood supply in developed and developing nations will compound over time. Red cell substitutes shave a promising value proposition for transfusion services, because they hold the promise of increasing the availability of blood products and removing donor and contamination safety risks. In this article, the authors note that existing products suffer from critical shortcomings such as vasoactivity; they also point out that substitutes not based on human blood introduce potentially more complex safety hurdles. The authors discuss the attributes of an ideal blood substitute, and the mechanism and current status of perfluorocarbons; they also review the shortcomings of all oxygen therapeutic products in development today.
引用
收藏
页码:399 / +
页数:17
相关论文
共 46 条
[1]  
Ali AA, 2001, ANESTH ANALG, V92, P863
[2]   Mammalian life without red blood corpuscles [J].
Amberson, WR ;
Mulder, AG ;
Steggerda, FR ;
Flexner, J ;
Pankratz, DS .
SCIENCE, 1933, 78 :106-107
[3]   THE EFFECTS OF HEMOGLOBIN SOLUTIONS ON RENAL FUNCTIONS IN MAN [J].
BRANDT, JL ;
FRANK, NR ;
LICHTMAN, HC .
BLOOD, 1951, 6 (11) :1152-1158
[4]  
BUCALA R, 1983, SCIENCE, V220, P965, DOI 10.1126/science.6844922
[5]   Clearance of prions during plasma protein manufacture [J].
Burdick, MD ;
Pifat, DY ;
Petteway, SR ;
Cai, K .
TRANSFUSION MEDICINE REVIEWS, 2006, 20 (01) :57-62
[6]  
Callas DD, 1997, CLIN CHEM, V43, P1744
[7]   SURVIVAL OF MAMMALS BREATHING ORGANIC LIQUIDS EQUILIBRATED WITH OXYGEN AT ATMOSPHERIC PRESSURE [J].
CLARK, LC ;
GOLLAN, F .
SCIENCE, 1966, 152 (3730) :1755-&
[8]   Experimental subarachnoid hemorrhage in rats - Effect of intravenous alpha-alpha diaspirin crosslinked hemoglobin on hypoperfusion and neuronal death [J].
Cole, DJ ;
Nary, JC ;
Reynolds, LW ;
Patel, PM ;
Drummond, JC .
ANESTHESIOLOGY, 1997, 87 (06) :1486-1493
[9]   A second-generation blood substitute (perfluorodichlorooctane emulsion) generates spurious elevations in platelet counts from automated hematology analyzers [J].
Cuignet, OY ;
Wood, BL ;
Chandler, WL ;
Spiess, BD .
ANESTHESIA AND ANALGESIA, 2000, 90 (03) :517-522
[10]   The future of clinical trials evaluating blood substitutes [J].
Fergusson, Dean A. ;
McIntyre, Lauralyn .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 299 (19) :2324-2326