Use of Intraoperative X-rays to Optimize Component Position and Leg Length During Total Hip Arthroplasty

被引:49
作者
Ezzet, Kace A. [1 ]
McCauley, Julie C. [2 ]
机构
[1] Scripps Clin, Div Orthopaed Surg, La Jolla, CA 92037 USA
[2] Scripps Hlth, Scripps Clin, Shiley Ctr Orthopaed Res & Educ, La Jolla, CA USA
关键词
total hip component alignment; hip navigation; hip radiographs; intraoperative hip radiographs; total hip arthroplasty; CEMENTLESS FEMORAL STEM; ACETABULAR COMPONENT; REPLACEMENT ARTHROPLASTIES; IMAGELESS NAVIGATION; FOLLOW-UP; RANGE; MOTION; ORIENTATION; DISLOCATION; INSERTION;
D O I
10.1016/j.arth.2013.08.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Proper femoral and acetabular component position and leg length equality are important intraoperative considerations during total hip arthroplasty. Unfortunately, traditional surgical techniques often lead to suboptimal component position, and such deviations have been associated with increased rates of prosthetic wear, dislocation, component loosening, and patient dissatisfaction. Although surgical navigation has been shown to improve reproducibility of component alignment, such technology is not universally available and is associated with significant costs and additional surgical/anesthetic time. In the current study, we found that a routine intraoperative pelvic radiograph could successfully identify malpositioned components and leg length inequalities and could allow for successful correction of identified problems. Unexpected component malposition and leg length inequality occurred in only 1.5% of cases where an intraoperative pelvic radiograph was utilized. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:580 / 585
页数:6
相关论文
共 28 条
[1]
ABRAHAM WD, 1992, ORTHOP CLIN N AM, V23, P201
[2]
Ceramic acetabular cups for total hip replacement - Part 6: Cup design, inclination angle and antetorsion angle have an influence on the range of motion and impingement [J].
Bader, R ;
Willmann, G .
BIOMEDIZINISCHE TECHNIK, 1999, 44 (7-8) :212-219
[3]
Barrack Robert L, 2003, J Am Acad Orthop Surg, V11, P89
[4]
Tapered cementless femoral stem: Difficult to place in varus but performs well in those rare cases [J].
Berend, Keith R. ;
Mallory, Thomas H. ;
Lombardi, Adolph V., Jr. ;
Dodds, Kathleen L. ;
Adams, Joanne B. .
ORTHOPEDICS, 2007, 30 (04) :295-297
[5]
Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
[6]
Accuracy measurements of acetabular cup positioning using CT less navigation [J].
Blendea, S. ;
Troccaz, J. ;
Merloz, R. .
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (02) :157-164
[7]
AN ANALYSIS OF 119 LOOSENINGS IN TOTAL HIP ENDOPROSTHESES [J].
BOSCH, P ;
KRISTEN, H ;
ZWEYMULLER, K .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1980, 96 (02) :83-90
[8]
Poor accuracy of freehand cup positioning during total hip arthroplasty [J].
Bosker, B. H. ;
Verheyen, C. C. P. M. ;
Horstmann, W. G. ;
Tulp, N. J. A. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (05) :375-379
[9]
The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[10]
16- to 25-year follow-up study of cemented arthroplasty of the hip in patients aged 50 years or younger [J].
Devitt, A ;
OSullivan, T ;
Quinlan, W .
JOURNAL OF ARTHROPLASTY, 1997, 12 (05) :479-489