The application of three-dimensional quantitative computed tomography to the maxillofacial skeleton

被引:23
作者
Maki, K
Okano, T
Morohashi, T
Yamada, S
Shibaski, Y
机构
[1] Department of Orthodontics, Showa University, Dental Hospital, Ohta-ku, Tokyo, 145
[2] Department of Oral Radiology, Showa University, Dental Hospital, Ohta-ku, Tokyo, 145
[3] Department of Pharmacology, Showa University, Dental Hospital, Ohta-ku, Tokyo, 145
关键词
bone and bones; tomography; X-ray computed; hydroxyapatites; facial bones;
D O I
10.1038/sj.dmfr.4600220
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Objectives: To develop a method for three-dimensional quantitative computed tomography (QCT) of the maxillofacial skeleton. Methods: The linearity of reference phantom consisting of five hydroxyapatite (HA) rods was tested under various conditions, including the size of field of view, the position of object, and reconstruction algorithm, on three different scanners. The calibrated HA concentration value and the absolute Ca content of the mandible removed from fresh cadaver was compared in order to evaluate the calibration error. Results: There was a high correlation between average CT number and HA concentration in the phantom rods. There was a 4-5% difference in results from the three scanners, High density areas, corresponding to more than 75% HA, were extracted from the original image. Data were reconstructed three-dimensionally and combined using a 32-bit computer system. A three-dimensional distribution of bone density superimposed on the maxillofacial skeleton was produced. Conclusion: Three-dimensional QCT of the maxillofacial skeleton has potential as a means of analysing bone density. Difference in performance of different CT scanners should be considered when comparing results.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 22 条
[1]
RELATIONSHIP OF BONE STRENGTH AND BONE QUANITITY IN HEALTH DISEASE AND AGING [J].
BARTLEY, MH ;
ARNOLD, JS ;
HASLAM, RK ;
JEE, WSS .
JOURNALS OF GERONTOLOGY, 1966, 21 (04) :517-&
[2]
Cameron J R, 1968, Invest Radiol, V3, P141, DOI 10.1097/00004424-196805000-00001
[3]
CAMERON JR, 1963, SCIENCE, V142, P230
[4]
PRECISE MEASUREMENT OF VERTEBRAL MINERAL-CONTENT USING COMPUTED-TOMOGRAPHY [J].
CANN, CE ;
GENANT, HK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (04) :493-500
[5]
BONE COMPRESSIVE STRENGTH - INFLUENCE OF DENSITY AND STRAIN RATE [J].
CARTER, DR ;
HAYES, WC .
SCIENCE, 1976, 194 (4270) :1174-1176
[6]
CHRISTIANSEN C, 1987, Lancet, V1, P1105
[7]
COHN AJ, 1985, AM J MED, V78, P95
[8]
EVALUATION OF THE SINGH INDEX AND FEMORAL CALCAR WIDTH AS EPIDEMIOLOGIC METHODS FOR MEASURING BONE MASS IN THE FEMORAL-NECK [J].
COOPER, C ;
BARKER, DJP ;
HALL, AJ .
CLINICAL RADIOLOGY, 1986, 37 (02) :123-125
[9]
X-RAY DUAL-PHOTON ABSORPTIOMETRY - A NEW METHOD FOR THE MEASUREMENT OF BONE-DENSITY [J].
CULLUM, ID ;
ELL, PJ ;
RYDER, JP .
BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (739) :587-592
[10]
Currey JD, 1984, MECH ADAPTATION BONE, P133