Hadamard transform capillary electrophoresis combined with absorption spectrometry

被引:34
作者
Hata, K [1 ]
Kaneta, T [1 ]
Imasaka, T [1 ]
机构
[1] Kyushu Univ, Grad Sch Engn, Dept Appl Chem, Fukuoka 8128581, Japan
关键词
D O I
10.1021/ac035366j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel injection device for applying absorption spectrometty to Hadamard transform (HT) capillary electrophoresis is described. A small hole, at the center part of the capillary, functions as an inlet port for the sample. The hole is immersed in a sample solution and the end of the capillary that is usually employed for sample introduction is immersed in a buffer solution. An ultraviolet absorption detector is placed between the sample injection port and the other end of the capillary filled with a buffer solution. A high potential is continuously applied between the injection port and the end of the capillary, which allows the sample solution to be introduced into the separation capillary. By application of a higher potential modulated according to a Hadamard code between both ends of the capillary, the buffer solution is injected into the separation capillary. In some preliminary experiments, this injection device was utilized to introduce a single sample segment into a capillary. As expected, a single peak was observed in the electropherogram for a sample containing a single component. This device was then employed for multiple sample injection in HT capillary electrophoresis. An 8-fold improvement in the S/N ratio was observed when the HT technique was used, in which a 255-order of a Hadamard matrix was used, as expected from theory. The present approach was also utilized for the sensitive detection of a sample comprised of multiple components.
引用
收藏
页码:4421 / 4425
页数:5
相关论文
共 27 条
[1]   AUXILIARY ELECTROOSMOTIC FLOW FOR POSTCAPILLARY REACTION DETECTION IN CAPILLARY ELECTROPHORESIS [J].
CASSIDY, RM ;
LU, WZ ;
TSE, VP .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :2578-2583
[2]   Shah convolution Fourier transform detection [J].
Crabtree, HJ ;
Kopp, MU ;
Manz, A .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2130-2138
[3]   Ultrasensitive cross correlation electrophoresis on microchip devices [J].
Fister, JC ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4460-4464
[4]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[5]  
Harwit M., 1979, Hadamard Transform Optics
[6]   Hadamard transform microchip electrophoresis combined with diode laser fluorometry [J].
Hata, K ;
Kichise, Y ;
Kaneta, T ;
Imasaka, T .
ANALYTICAL CHEMISTRY, 2003, 75 (07) :1765-1768
[7]   USE OF AN ON-COLUMN FRIT IN CAPILLARY ZONE ELECTROPHORESIS - SAMPLE COLLECTION [J].
HUANG, XH ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1990, 62 (05) :443-446
[8]   Application of Hadamard transformation to chiral separation by capillary electrophoresis [J].
Kaneta, T ;
Nishida, M ;
Imasaka, T .
BUNSEKI KAGAKU, 2003, 52 (12) :1193-1197
[9]   Ultratrace analysis based on Hadamard transform capillary electrophoresis [J].
Kaneta, T ;
Kosai, K ;
Imasaka, T .
ANALYTICAL CHEMISTRY, 2002, 74 (10) :2257-2260
[10]   Hadamard transform capillary electrophoresis. [J].
Kaneta, T .
ANALYTICAL CHEMISTRY, 2001, 73 (19) :540A-547A