American College of Cardiology/European Society of Cardiology international study of angiographic data compression phase I - The effects of lossy data compression on recognition of diagnostic features in digital coronary angiography

被引:21
作者
Kerensky, RA
Cusma, JT
Kubilis, P
Simon, R
Bashore, TM
Hirshfeld, JW
Holmes, DR
Pepine, CJ
Nissen, SE
机构
[1] Univ Florida, Cardiol Sect, Gainesville, FL 32610 USA
[2] Cleveland Clin Fdn, Cleveland, OH 44195 USA
[3] Duke Univ, Durham, NC USA
[4] Mayo Clin, Rochester, MN USA
[5] Univ Kiel, Kiel, Germany
[6] Univ Penn, Philadelphia, PA 19104 USA
关键词
D O I
10.1016/S0735-1097(99)00610-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study intended to determine the effect of varying degrees of lossy Joint Photographic Experts Group (JPEG) compression on detection of coronary angiographic features, BACKGROUND Compression of digital coronary angiograms facilitates playback of images and decreases cost. There are little data on the effect of compression on the accuracy of coronary angiography. METHODS At six centers, 71 angiographers each reviewed a set of 100 angiographic sequences. The 100 sequences were divided into four, 25-sequence subsets. Each subset of 25 was displayed either as original images or at one of three compression ratios (CRs) (6:1, 10:1 or 16:1). The effect of lossy compression on the sensitivity and specificity for detection of diagnostic features was determined. The effect of compression on subjective measures of image quality graded by the angiographers was also examined. RESULTS Lossy compression at a ratio of 16:1 decreased the sensitivity for the detection of diagnostic features (76% vs. 80% p = 0.004). The largest effect was in the detection of calcification (52% vs. 63% at 16:1 compression vs. original images, p < 0.001). Subjective indicators of image quality indicated a reduction in confidence in interpretation at CRs of 10:1 and 16:1. CONCLUSIONS With increased ratios of lossy compression, a degradation of digital coronary angiograms occurs that results in decreased diagnostic accuracy. The sensitivity fur detection of common diagnostic features was decreased, and subjective assessment of image quality was impaired. Caution is warranted in the interpretation of coronary angiograms that have been subjected to lossy JPEG compression beyond a ratio of 6:1. a Am Coil Cardiol 2000;35:1370-9) (C) 2000 by the American College of Cardiology.
引用
收藏
页码:1370 / 1379
页数:10
相关论文
共 23 条
[1]   Lossy (15:1) JPEG compression of digital coronary angiograms does not limit detection of subtle morphological features [J].
Baker, WA ;
Hearne, SE ;
Spero, LA ;
Morris, KG ;
Harrington, RA ;
Sketch, MH ;
Behar, VS ;
Kong, YH ;
Peter, RH ;
Bashore, TM ;
Harrison, JK ;
Cusma, JT .
CIRCULATION, 1997, 96 (04) :1157-1164
[2]   ACCURACY OF INDIVIDUAL AND PANEL VISUAL INTERPRETATIONS OF CORONARY ARTERIOGRAMS - IMPLICATIONS FOR CLINICAL DECISIONS [J].
BEAUMAN, GJ ;
VOGEL, RA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (01) :108-113
[3]   IMAGE DATA-COMPRESSION [J].
BRAMBLE, JM ;
HUANG, HK ;
MURPHY, MD .
INVESTIGATIVE RADIOLOGY, 1988, 23 (10) :707-712
[4]  
BRENNECKE R, 1992, IEEE COMPUT CARDIOL, P259
[5]   REQUIREMENTS FOR CARDIAC INTERCHANGE MEDIA AND THE ROLE OF RECORDABLE CD [J].
CONDIT, PB .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1995, 11 :153-157
[6]  
Cusma J T, 1994, Int J Card Imaging, V10, P165, DOI 10.1007/BF01137898
[7]   VARIABILITY IN ANALYSIS OF CORONARY ARTERIOGRAMS [J].
DEROUEN, TA ;
MURRAY, JA ;
OWEN, W .
CIRCULATION, 1977, 55 (02) :324-328
[8]   OBSERVER AGREEMENT IN EVALUATING CORONARY ANGIOGRAMS [J].
DETRE, KM ;
WRIGHT, E ;
MURPHY, ML ;
TAKARO, T .
CIRCULATION, 1975, 52 (06) :979-986
[9]   REPRODUCIBILITY OF CORONARY ARTERIOGRAPHIC READING IN THE CORONARY-ARTERY SURGERY STUDY (CASS) [J].
FISHER, LD ;
JUDKINS, MP ;
LESPERANCE, J ;
CAMERON, A ;
SWAYE, P ;
RYAN, T ;
MAYNARD, C ;
BOURASSA, M ;
KENNEDY, JW ;
GOSSELIN, A ;
KEMP, H ;
FAXON, D ;
WEXLER, L ;
DAVIS, KB .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1982, 8 (06) :565-575
[10]  
Holmes DR, 1998, CATHETER CARDIO DIAG, V44, P346